Installing And Connecting; Attaching An "N" Connector; Power Supply Requirements - Icom ID-RP4000V Instruction Manual

Uhf digital voice repeater
Hide thumbs Also See for ID-RP4000V:
Table of Contents

Advertisement

3

INSTALLING AND CONNECTING

Attaching an "N" connector

Nut Rubber gasket
q
15 mm
Washer
w
Center
Clamp
conductor
3 mm
6 mm
e
Solder hole
No space
r
Be sure the center conductor is
the same height as the plug body.
15 mm (0.59 in) 6 mm (0.24 in) 3 mm (0.12 in)

Power supply requirements

Slide
the
nut,
washer,
rubber gasket and clamp
over the coaxial cable, then
cut the end of the cable
evenly.
Strip the cable and fold the
braid back over the clamp.
Tin the center conductor.
Install the center conductor
pin and solder it.
Carefully slide the plug
body into place aligning the
center conductor pin on the
cable. Tighten the nut onto
the plug body.
Use 50 ø connectors and coax cable.
Use "N" type connectors between the repeater and the
antennas.
RECOMMENDATION: Install a lightning protector
between the ID-RP4000V and the antenna.
Make sure that the DC power supply that is used with
the ID-RP4000V system meets the following require-
ments:
Output voltage:
13.8 V DC ±15%
Current capacity: At least the total current consumption
of the connected equipment.