Step 15 (conditional): Remove the cable management arms
To remove a cable management arm:
1. Using the #1 Phillips screwdriver, loosen the large black screw that
attaches the cable management arm to the middle of the enclosure until
the screw is very loose. The screw does not come out.
2. Pull the cable management arm away from the enclosure, allowing the
small stud on the left arm to slide out of the slot on the right arm.
3. While pushing in the tabs on both sides of the front of the enclosure
behind the front panel, pull the enclosure forward a few inches out of the
rack.
4. Unwrap and remove the five Velcro strips that are wrapped around the
power cable in the cable management arm. Place the Velcro strips in the
enclosure accessory box.
5. Move the power cable out of the cable management arm, passing the
cable out through the opening at the rack end of the arm.
6. Place the power cable in the enclosure accessory box.