8.1 Specifications

8.1 Specifications

Model No.
Power supply voltage
Current consumption
(Note 2)
Output type
Applied voltage
Residual voltage
Maximum sink
current / source
current
Leakage current
Output operation
Short-circuit
protection
Analog output
Output range
Output impedance
Output range
Load resistance
Input conditions
Input impedance
External input function
8-2
Ramco Innovations www.ramcoi.com Got Questions? Phone 800-280-6933 Email nsales@ramcoi.com
HG-F13A-A-N
NPN output type
24 VDC ±10%, including 10% ripple (P-P)
40 mA or less (at the power supply voltage of 24 VDC)
NPN open-collector transistor
30 VDC (between output and 0 V)
1.5 V or less (at 50 mA source current)
Maximum sink current: 50 mA
Light-ON (L-on)/dark-ON (d-on)
Selectable (Default: Light-ON (L-on))
Incorporated (automatic reset type)
Voltage output / current output, selectable (Default: Voltage output)
In normal condition: 0 V to +5 V
Possible to set the distance range (Default: 250 to 3,000 mm)
When alarm occurs: Last value is held or the range is set to 0 V on the near point
side and to +5.2 V on the far point side.
In normal condition: +4 mA to +20 mA
Possible to set the distance range (Default: 250 to 3,000 mm)
When alarm occurs: Last value is held or the range is set to 0 mA on the near point
side and to +20.8 mA on the far point side.
Disabled: 8 to +VDC or open
Enabled: 0 to 1.2 VDC
Zero set / Teaching / Emission stop
PNP open-collector transistor
30 VDC (between output and +V)
Maximum source current: 50 mA
0.1 mA or less
100 Ω
250 Ω or less
Disabled: 0 to 0.6 VDC or open
Enabled: 4 to + VDC
Approx. 10 kΩ
Selectable (Default: Zero set)
HG-F13A-A-P
PNP output type
WUME-HGF1UM-2