Teaching; Emission Stop - Panasonic HG-F Series User Manual

Long range laser distance sensor
Table of Contents

Advertisement

● The zero set that is set using the external input is cleared when the power supply is turned
OFF. The zero set made at that time is not saved.
● Even when the zero set is set on the sensor side, it can be set or cleared using the external
input. However, the zero set on the sensor side is not cleared.
When the power supply is turned on again, the zero set that is set on the sensor side will be
displayed.
● When zero setting is performed during teaching, using the external input, teaching becomes
unstable.

5.14.2 Teaching

This setting is used to execute teaching by controlling the external input in the same manner as
when the TEACH key is pressed.
● For details on teaching, refer to
● The timing chart for executing teaching using the external input is as shown in the following
diagram.
● Limit teaching cannot be executed by the external input alone.
● Teaching using the external input is not accepted in the PRO mode.

5.14.3 Emission Stop

This setting is used to turn ON or OFF the emitted laser beam using the external input.

Emission stop

● The emitted laser beam can be turned OFF by turning ON the external input from OFF. The
laser radiation indicator is also unlit when the emitted laser beam is turned OFF.
WUME-HGF1UM-2
Ramco Innovations www.ramcoi.com Got Questions? Phone 800-280-6933 Email nsales@ramcoi.com