SPECIFICATIONS

Type
Item
Model No.
Applicable regulations and
certifications
Measurable range
Displayable range (Note 2)
Repeatability
Hysteresis
Linearity
Temperature characteristics
Light source
Beam diameter (Note 6)
Supply voltage
Power consumption (Note 7)
NPN open-collector transistor
• Maximum sink current: 50 mA
Control output
• Applied voltage: 30 V DC or less (Between control output to 0 V)
• Residual voltage: 1.5 V or less (At 50 mA sink current)
• Leakage current: 0.1 mA or less
Output
operation
Short-circuit
protection
Analog output
Output range
Analog
voltage
Output
output
impedance
• In normal operation: +4 to +20 mA Possible to set the distance range (Default: 250 to 3,000 mm
Output range
Analog
• When alarm occurs: Last value is held or the range is set to 0 mA on the near point side and to +20.8 mA on the far point side.
current
Output
output
impedance
Response time
External input
External input function
Teaching function
Timer function
Timer period
Pollution degree
Overvoltage category
Ambient altitude (Note 8)
Protection
Ambient temperature
Ambient humidity
Ambient illuminance
Vibration resistance
Shock resistance
Cable
Cable extension
Material
Weight
Notes: 1 ) Unless otherwise specified, measurement conditions are as follows: Power supply voltage of 24 VDC, ambient temperature of +20 °C +68 °F, response
time of 100 ms, and measuring distance of 1,000 mm
Perform measurement 30 minutes after turning on the power supply.
2) When an object is detected, the range of numerical values that appear on the digital display is regarded as the displayable distance. When zero setting
is performed, the displayable distance varies depending on the zero setting distance.
3) Changing the hysteresis may result in unstable sensing. After making a change, perform operation check using actual equipment.
4) F.S. (full scale) represents a range from 0 mm to 3,000 mm
5) This product complies with the FDA regulations (FDA 21 CFR 1040.10 and 1040.11) in accordance with FDA Laser Notice No. 56, except for complying
with IEC 60825-1 Ed. 3.
6) The beam diameter is defined as 1/e
may be affected if the reflectance around the detecting point is higher than that of the detecting point.
7) Analog output is not included.
8) Do not use or store this product in environments where ambient air is pressurized to an air pressure higher than the atmospheric pressure at an altitude
of 0 m.
NPN output type
HG-F13A-A-N
CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations),
FDA Regulations, TÜV SÜD NRTL certification (USA, Canada)
30 mm
1.181 in
(default setting) Possible to vary up to 1 mm
± 2% F.S. (Note 4) (at a measuring distance of 500 mm to 3,000 mm
Red semiconductor laser: Class 1 [JIS / IEC / GB / KS / FDA (Note 5)]
Maximum output: 0.39 mW, Peak emission wavelength: 680 nm
Approx. ø10 mm
ø0.394 in
Switchable between Light-ON / Dark-ON, (Default: Light-ON)
Switchable between voltage output / current output (Default: voltage output)
• In normal operation: 0 to +5 V Possible to set the distance range (Default: 250 to 3,000 mm
• When alarm occurs: Last value is held or the range is set to 0 V on the near point side and to +5.2 V on the far point side.
Switchable between 35 ms / 100 ms / 300 ms / 2,000 ms (Default: 100 ms)
NPN non-contact input
• Input condition
Invalid: +8 to + V DC or Open
Valid: 0 to +1.2 V DC
• Input impedance: approx. 10 kΩ
Switchable between zero set, teaching, or emission stop (Default: zero set)
Switchable between normal sensing mode (2-point / limit) or window comparator mode (1-point / 2-point / 3-point)
(Default: Normal sensing mode)
Switchable between OFF / ON delay / OFF delay / one-shot (Default: OFF)
Switchable between 5 ms / 10 ms / 25 ms / 50 ms / 100 ms / 250 ms / 500 ms / 1,000 ms / 5,000 ms (Default: 5 ms)
-10 to +45 °C +14 to 113 °F (No dew condensation or icing allowed), Storage: -20 to +60 °C -4 to 140 °F
Incandescent light: 3,000 ℓx or less at the light-receiving face
10 to 55 Hz (period: 1 min.) frequency, 1.5 mm
2
500 m/s
acceleration (approx. 50 G) in X, Y and Z directions three times each
0.2 mm
Extension up to total 10 m
Enclosure: Aluminum die-cast, Front cover: Acrylic, Cable: PVC
Net weight: approx. 85 g, Gross weight: approx. 130 g
39.370
in. The target object is a 200 mm × 200 mm
0 in to 118.110
(approx. 13.5%) of the center light intensity. Due to leak light outside the defined range, the measurement values
2
250 to 3,000 mm
9.843 in to 118.110 in
200 to 3,300 mm
7.874 in to 129.921 in
±10 mm
0.394 in
or less
0.039 in
0.1% F.S./°C
(typical) (at the measuring distance of 1,000 mm
24 V DC ±10%, Ripple P-P 10%
40 mA or less (at 24 V DC supply voltage)
PNP open-collector transistor
• Maximum source current: 50 mA
• Applied voltage: 30 V DC or less (Between control output to +V)
• Residual voltage: 1.5 V or less (At 50 mA source current)
• Leakage current: 0.1 mA or less
Incorporated (Auto reset type)
100 Ω
250 Ω or less
PNP non-contact input
2
Category I
2,000 m
6561.680 ft
or less
IP67 (IEC)
35 to 85% RH, Storage: 35 to 85% RH
0.059 in
double amplitude in X, Y and Z directions for two hours each
2
5-core composite cable, 2 m
6.562 ft
32.808 ft
is possible with 0.3 mm
in.
PNP output type
HG-F13A-A-P
minimum in the PRO mode (Note 3)
19.685 in to 118.110
in)
0.0268 mil
39.370
in)
9.843 in to 118.110
9.843 in to 118.110
• Input condition
Invalid: 0 to +0.6 V DC or Open
Valid: +4 to +V DC
• Input impedance: approx. 10 kΩ
long
2
, or more, cable
7.874 in ×7.874 in