8.1 Specifications
Model No.
Operating altitude (Note
8)
Various settings
Protective structure
Ambient operating
temperature
Ambient operating
humidity
Ambient illuminance
Vibration resistance
Shock resistance
Cable
Cable extension
Materials
Weight
(Note 1)
Unless otherwise specified, measurement conditions are as follows: Power supply voltage of 24 VDC,
ambient temperature of +20℃, response time of 100 ms, and measurement distance of 1,000 mm.
The target object is a 200 mm × 200 mm white matte paper. Perform measurement 30 minutes after
turning on the power supply.
(Note 2)
Analog output is not included.
(Note 3)
When an object is detected, the range of numerical values that appear on the digital display is
regarded as the displayable distance.
When zero setting is performed, the displayable distance varies depending on the zero setting
distance.
(Note 4)
F.S. (full scale) represents a range from 0 mm to 3,000 mm.
(Note 5)
This product complies with the FDA regulations (FDA 21 CFR 1040.10 and 1040.11) in accordance
with FDA Laser Notice No. 56, except for complying with IEC 60825-1 Ed. 3.
(Note 6)
The beam diameter is defined as 1/e
outside the defined range, the measurement values may be affected if the reflectance around the
detecting point is higher than that of the detecting point.
(Note 7)
Changing the hysteresis may result in unstable sensing. After making a change, perform operation
check using actual equipment.
(Note 8)
Do not use or store this product in environments where ambient air is pressurized to an air pressure
higher than the atmospheric pressure at an altitude of 0 m.
8-4
Ramco Innovations www.ramcoi.com Got Questions? Phone 800-280-6933 Email nsales@ramcoi.com
HG-F13A-A-N
NPN output type
Emitted beam spot check mode / Threshold fine adjustment / Threshold selectable /
Peak/bottom hold function / Zero set function / Key lock function / Response time
setting / Output operation setting / Sensing output setting (teaching) / Analog output
setting / Analog scaling setting / Hysteresis setting / Shift amount setting / External
input setting / Timer setting / Timer time setting / Hold setting / ECO setting / Reset
setting
-10 to +45 °C (No condensation or icing), Storage: -20 to +60 °C
35% to 85% RH, Storage: 35% to 85% RH
Incandescent light: 3,000 lx or less at the light-receiving face
Durability:10 to 55 Hz (cycle: 1 minute) with 1.5 mm amplitude in X, Y, and Z
directions for two hours each (with no power supply)
2
Durability: 500 m/s
(approx. 50 G) in X, Y and Z directions three times each (with no
0.2 mm
Extension up to total 10 m is possible with a cable of 0.3 mm
Casing: Aluminum die casting, Front cover: Acrylic, Cable: PVC
Approx. 85 g, approx 130 g (when packaged)
2
(approx. 13.5 %) of the center light intensity. Due to leak light
2,000 m or less
IP67 (IEC)
power supply)
2
5-conductor 2 m composite cable
HG-F13A-A-P
PNP output type
2
or more.
WUME-HGF1UM-2