FLEX 5000 2-channel Isolated-frequency Input Modules Installation Instructions
Electrical Safety Considerations
ATTENTION:
• All wiring must comply with applicable electrical installation requirements [N.E.C. article 501-4(b)].
• Wire conductor and insulation ratings shall support a minimum temperature rating of 105 °C (221 °F).
• Do not wire more than one conductor on any terminal.
• In case of malfunction or damage, no attempts at repair should be made. The module should be returned to the manufacturer for repair. Do not dismantle
the module.
• This equipment is certified for use only within the surrounding air temperature range of -40...+70 °C (-40...+158 °F) The equipment must not be used outside
of this range.
• Use only a soft dry anti-static cloth to wipe down equipment. Do not use any cleaning agents.
Environment and Enclosure
ATTENTION: This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as defined in
EN/IEC 60664-1), at altitudes up to 2000 m (6562 ft) without derating.
This equipment is not intended for use in residential environments and may not provide adequate protection to radio communication services in such
environments.
This equipment is supplied as open-type equipment for indoor use. It must be mounted within an enclosure that is suitably designed for those specific
environmental conditions that will be present and appropriately designed to help prevent personal injury resulting from accessibility to live parts. The
enclosure must have suitable flame-retardant properties to help prevent or minimize the spread of flame, complying with a flame spread rating of 5VA or be
approved for the application if nonmetallic. The interior of the enclosure must be accessible only by the use of a tool. Subsequent sections of this publication
may contain additional information regarding specific enclosure type ratings that are required to comply with certain product safety certifications.
In addition to this publication, see the following:
• Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1, for more installation requirements.
• NEMA Standard 250 and EN/IEC 60529, as applicable, for explanations of the degrees of protection provided by enclosures.
ATTENTION: Personnel responsible for the application of safety-related programmable electronic systems (PES) shall be aware of the safety requirements in
the application of the system and shall be trained in using the system.
IMPORTANT
Any illustrations, charts, sample programs, and layout examples that are shown in this publication are intended solely for the purposes of example. Since
there are many variables and requirements that are associated with any particular installation, Rockwell Automation does not assume responsibility or
liability for actual use based on the examples that are shown in this publication.

About the Module

FRONT VIEW
®

Install a FLEX 5000 I/O System

Before you install the module, you must install a FLEX 5000 I/O system. At minimum, the system must include a FLEX 5000 EtherNet/IP™ adapter and backplane end cap.
For more information on how to install a FLEX 5000 I/O system, see the FLEX 5000 EtherNet/IP Adapters with RJ45 Ports Installation Instructions, publication 5094-IN001, and the
FLEX 5000 Terminal Base Assembly Modules Installation Instructions, publication 5094-IN010.
You can install the module next to any FLEX 5000 I/O module.
IMPORTANT
See the FLEX 5000 Standard and Safety Frequency Input Modules User Manual, publication 5094-UM004, for firmware and software requirements.
4
Module release lever
Keyswitch ports
Module status indicator
SA power indicator
Slide-in writable label
Terminal base requirement
I/O status indicators
Keyswitch position
Rockwell Automation Publication 5094-IN029A-EN-P - February 2023