2
GENERAL INFORMATION
2.1
Appliance performance
Fuel type
Recommended heating area
Firebox volume
Maximum burn time
Overall heat output rate (min. to max)
Average overall efficiency
Optimum efficiency
Average particulate emissions rate
(8)
Average CO
[*]
Recommended heating area and maximum burn time may vary subject to location in home, chimney draft, heat
loss factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined
by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case
of a power failure.
(1)
Values are as measured per test method, except for the recommended heating area, firebox volume, maximum
burn time and maximum heat output.
(2)
The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft
Other performances are based on a fuel load prescribed by the standard. The specified loading density varies
3
between 7 lb/ft
and 12 lb/ft
(3)
As measured per CSA B415.1-10 stack loss method.
(4)
Higher Heating Value of the fuel.
(5)
Lower Heating Value of the fuel.
(6)
Optimum overall efficiency at a specific burn rate (LHV).
(7)
This appliance is officially tested and certified by an independent agency.
(8)
Carbon monoxide.
8
(1)
[*]
[*]
(2)(3)
(3)
- Dry cordwood
(2)(6)
(7)
3
. The moisture content is between 19% and 25%.
Dry cordwood
2
1,000 to 2,800 ft
(93 to 260 m
3
3
4,28 ft
(0,113 m
)
11 h
16,900 BTU/h to 43,000 BTU/h
(5.0 kW to 12,6 kW)
(4)
64.0% (HHV
)
70.0%
1.6 g/h (EPA)
159.0 g/h
HORIZON – Installation and Operation Manual
2
)
(5)
69.0% (LHV
)
3
and 20 lb/ft
3
.