Advertisement

6.3.7.3 Framing for a corner installation
VALUES (M) AND (N) ARE MINIMUM MEASUREMENTS. THEY MAY NEED TO BE INCREASED TO ALLOW
INSTALLATION OF A FRESH AIR INTAKE KIT OR FORCED AIR KIT, OR DEPENDING ON THE FINISH
MATERIAL USED.
Refer to the building code or the local code for regulations concerning the need to install finishing material
inside the chase around the fireplace.

6.3.8 Facing

Materials directly in the front of the fireplace, must be
shown on the following figure.
Non-combustible materials such as brick, stone or ceramic tile may project in front of and onto the fireplace
decorative frame.
MATERIALS MUST BE INSTALLED SO THAT THE FACEPLATE MAY BE REMOVED AFTER THE INSTALLATION.
THE FACEPLATE IS DESIGNED TO OVERLAP THE MATERIAL SURROUNDING THE FIREPLACE. IF THE
MATERIAL IS THICKER, USE A FACEPLATE GAUGE FOR POSITIONING AND MAKE SURE THAT THE
FACEPLATE CAN BE REMOVED AFTER IT HAS BEEN INSTALLED.
46
CAUTION
MEASUREMENTS*
M
67 5/8" (1718 mm)
N
95 11/16" (2430 mm)
CAUTION
non-combustible and have the
HORIZON – Installation and Operation Manual
minimum dimensions