Ems Restart - Redback SH5000 Owner's Manual

Smart hybrid system
Hide thumbs Also See for SH5000:
Table of Contents

Advertisement

9.5

EMS restart

Occasionally, it may be necessary to restart the EMS software. A restart will reboot the EMS, without needing to restart the
whole inverter, noting that the backup circuit will be briefly interrupted.
DO NOT restart unless instructed to do so by Redback support staff.
STEP
PROCEDURE
Open the BoS switchgear hatch.
Identify the three-position Bypass switch. Note the position of the
switch.
Note: The switch is usually returned to the original position during
restart.
Set the Bypass switch to the middle position (OFF).
Wait 5 seconds.
Return the Bypass switch to its original position (if noted)
otherwise place in the DOWN position. The EMS will restart in
approximately 10 minutes, indicated by the EMS LEDs stabilising
to:
POWER
HEARTBEAT
INVERTER
BATTERY
NETWORK
BLUETOOTH
☐ Up
☐ Down
Green; ON
Red; FLASHING
Blue; ON
Blue; ON (if batteries are connected)
Blue; ON (if Network is OK)
Blue; FLASHING (for extra 30 minutes, then
OFF)
COMMENT/ILLUSTRATION
Owner's Guide – Redback Smart Hy brid System - v3.8
Redback Technolo gies
19