GENERAL INFORMATION
Operating Temperature
Unconditioned without solar effects
Operating Temperature Derated Output
Operating Relative Humidity
Operating Altitude
Protective Class
Ingress Protection Rating
AC Overvoltage Category
DC Overvoltage Category
Active Anti-islanding Method
Moisture Location Category
External Environment Pollution Degree
Inverter Topology
Country of Origin
Demand Response Modes
Standby Self-Consumption
Noise Emissions
Warranty
EFFICIENCY
Maximum Efficiency
Maximum Battery to Load Efficiency
European Efficiency
PHYSICAL DATA
Installed Weight (including SH5000, BE14000 and Batteries)
Dimensions (including PCE and BoS) (W x D x H)
Material
Finish
BE14000 Smart Hybrid Battery Enclosure Data
Number of Battery Units
Storage Capacity
Battery System Model
Maximum Capacity
Nominal Voltage
Rated Current
Fan Specification
Protective Class
Ingress Protection Rating
Dimensions (W x D x H)
Material
Finish
-25°C to 60°C
below 10°C and over 45°C
0 - 95%
0 - 3000m
I
IP65
OVC III
OVC II
Active Frequency Drift
4K4H
Grade 1, 2 and 3
Non-isolated
China
DRM 0
<13W
<30 dBm
10 Years
97.60%
94%
97%
132-203kg
518 x 360 x 840mm
Aluminium
Sealed and powder coated
2 to 4
4x 2.4kWh or 4x 3.55kWh
US2000 or US3000
14.2kWh
DC 48V
DC 100A
DC 48V / 0.13A x2
I
IP54
545x348x1125 mm
Steel
Sealed and powder coated
Owner's Guide – Redback Smart Hy brid System - v3.8
Redback Technolo gies
33