Inverter operation

Inverter operation
Your Redback inverter has sophisticated software controls available in the Redback app or portal, however there are some
physical controls or functions at the unit.

Locking up the batteries

Secure the Battery Enclosures to:
Prevent unauthorised access to the batteries.
Discourage battery theft.
The battery enclosures are secured by trapping the Front Covers: clamps at either
side are padlocked in position, restricting access to front cover fasteners, and
resisting forcing of the covers. Note: The security clamps will discourage a casual or
opportunistic intruder but will not stop a determined thief.

EMS restart

Occasionally, it may be necessary to restart the EMS. A restart will reboot the EMS,
without needing to restart the whole inverter, noting that the Backup circuit will
be briefly interrupted.
To restart the system, press the switch concealed under the spider.
Inverter – Changing bypass modes
The BYPASS switch controls the power to the BACKUP AC isolator. Its primary use
is to manually connect the backup circuit directly to grid supply, when required.
Position
Up
Middle
Down
16
Owner's Guide – Redback ST10000 and BE14000-HV – v1.6
Function
Power to the backup
circuit is from the grid
supply only.
The Inverter no longer
controls the backup circuit.
Backup circuit is isolated
(depowered).
Power to the backup
circuit is supplied and
managed by the Inverter,
from any source.
Comments
This mode ensures grid supply to the backup circuit if the
inverter is not available; not operating reliably; or if a large,
temporary load must be placed on the backup circuit.
If grid supply is lost the Inverter will not supply the backup
circuit.
No power is sent to the backup circuit.
This is the recommended Operational mode.
If grid supply is lost the Inverter will continue to supply the
backup circuit from the batteries and PV- the entire system will
shut down when the batteries reach the minimum state of
charge.