ERROR SHOWED ON
SCREEN
[LED AIR IN (LOW) FAN
ERR.]
[LED AIR OUT (UP) FAN
ERR.]
[POWER SUPPLY FAN
ERROR]
[BASE FAN 1 ERROR]
[BASE FAN 2 ERROR]
[PAN/TILT PCB ERROR]
[MOTOR PCB 2 ERROR]
[MOTOR PCB 3 ERROR]
[MOTOR PCB 4 ERROR]
[MOTOR PCB 5 ERROR]
[FAN PCB ERROR]
[FOCUS ERROR]
[GOBO WHEEL ERROR]
[4F PRISM ERROR]
[4F PRISM ROTATION
ERROR]
[FROST ERROR]
[CYAN ERROR]
[MAGENTA ERROR]
[YELLOW ERROR]
[GOBO ROTATION
ERROR]
[ZOOM ERROR]
[ANIMATION WHEEL
ERROR]
POSSIBLE CAUSES
Air in blower for cooling the lamp failed, the lamp has been
switched OFF.
Air out blower for cooling the lamp failed, the lamp has
been switched OFF.
Blower for cooling the power supply failed.
First of the blowers for cooling the base failed.
Second of the blowers for cooling the base failed.
Pan tilt pcb not detected.
Motor pcb 3U not detected.
Motor pcb 4U not detected.
Motor pcb 5U not detected.
Motor pcb 6U not detected.
Fan PCB not detected.
Failure detected during the reset of the FOCUS, if the focus
lens is not located in its default position.
Failure detected during the reset of the gobo wheel, if this
wheel is not located in the default position.
Failure detected during the reset of the 4F effect prism, if
this effect is not located in the default position.
Failure detected during the reset of the 4F effect prism rota-
tion, if this effect is not located in the default position.
Failure detected during the reset of the effect FROST, if this
effect is not located in the default position.
Failure detected during the reset of the Cyan flag, if the
Cyan flag of the CMY module is not located in its default
position.
Failure detected during the reset of the Magenta flag, if
the Magenta flag of the CMY module is not located in its
default position.
Failure detected during the reset of the Yellow flag, if the
Yellow flag of the CMY module is not located in its default
position.
Failure detected during the reset of the rotation of the
rotating gobo, if the rotating gobos are not located in the
default positions.
Failure detected during the reset of the ZOOM system, if
the focus lens is not located in its default position.
Failure detected during the reset of the animation wheel, if
this wheel is not located in the default position.
PROLIGHTS - Astra Profile600IP
POSSIBLE PCB
WITH ANOMALY
3U
3U
1U
1U
1U
2U
4U
5U
6U
7U
3U
7U
5U
7U
7U
7U
4U
4U
4U
5U
7U
5U