5.2. Status bar

Fig. 5.3: Status bar - Everything OK
The Status bar is located on the upper part of the screen below the title bar. It consists of 3 fields:
• Local unit status (unit assigned to the IP address entered in the browser or CLI)
• Link status (Local to Peer)
• Peer unit status
Local and Peer status field displays:
• Station name according to configuration.
• Actual time valid for respective unit.
• Warning or Alarm icon in case of warning or alarm.
Link status field displays:
• OK if the link is connected, Peer unit is authorized and user data are transmitted
• or Warning icon (a triangle) if the link is not capable of user data transfer, followed by a status of
the link (one of the following values):
UNKNOWN
Unit start up. The initialization is not yet finished.
SETUP
Unit initialization according to valid configuration.
SINGLE
Unit in operation status. Link to peer unit is not established.
CONNECTING
Connection to peer unit in progress.
AUTHORIZING
Authorization of the peer unit in progress.
ANALYZER
Spectrum analyzer mode active. User data are not transferred.
The example of a complete Status bar with active Alarm and Link not OK.
Fig. 5.4: Status bar - example of Alarm + Link not OK"
© RACOM s.r.o. – RAy3 Microwave Link
Configuration
81

Advertisement