Alarms Acknowledge - RACOM RAy3-11 User Manual

Microwave link
Table of Contents

Advertisement

Configuration

5.4.4.2. Alarms Acknowledge

Fig. 5.15: Menu Link settings > Alarms > Acknowledge
Alarm acknowledgement allows the operator to confirm the system is set in alarm state. Only an active
alarm can be acknowledged. Multiple selections of active alarms (to acknowledge groups of alarms)
can be performed using Shift or Ctrl keys.
Name
Alarm identification - The following alarms can appear: Inside temperature, Voltage min, Voltage
max, RSS, MSE, BER, Net bitrate, Air link, Eth1 link, Eth2 link, RF power, WiFi management
State
There are three possible alarm states:
OK — No alarm (alarm is inactive) or alarm disabled.
Ack — Alarm is active and acknowledged.
Alarm — Alarm is active and is not acknowledged.
From
Time stamp when the alarm occurred.
To
Time stamp when the alarm expired (returned to normal conditions).
Ack
Time stamp when the alarm was acknowledged. Time stamp format: yyyy-MM-dd hh:mm:ss
User
Name (login) of the user who acknowledged the alarm.
Comment
The comment field can be used to add user defined comments when an 'alarm acknowledge' is
performed. Use this comment field to describe important details of the alarm status. The comment
can be up to 50 characters long. Special characters are not allowed. The alarm can be acknowledged