Figure 1-3, Back Panel Features - Sensata Magnum Energy CSW3012-X Owner's Manual

Pure sine wave inverter
Table of Contents

Advertisement

The back panel of the CSW3012-X inverter is equipped with the following
features (See Figure 1-3):
11. Model Number – the model number of the inverter and other
information.
12. Cooling Fan(s) – intake cooling fans that automatically turn on when
the inverter's internal temperature rises above 122°F (50°C). The fan
turns off when the inverter's internal temperature falls below 122°F
(50°C).
13. Mounting Flanges (front and rear) – used to mount and secure the
inverter to a shelf/wall.
14. DC Ground Connection – the connection that is used to tie the
exposed chassis of the inverter to the DC grounding system. The DC
grounding system could be the vehicle's chassis, the DC grounding bus,
or the engine's negative bus. To attach ground wires, use a pressure or
mechanical connector (i.e., ring terminal) with a 1/4" opening. Ground
lug is located on side of unit.
15. DC Positive Terminal (red) – the inverter's connection to the positive
terminal on the 12 VDC battery bank.
16. DC Negative Terminal (black) – the inverter's connection to the
negative terminal on the 12 VDC battery bank.
11
12
13
14

Figure 1-3, Back Panel Features