Display Panel Operation; Figure 3-1, Display Panel; Table 3-1, Display Functions/Statuses - Sensata Magnum Energy CSW3012-X Owner's Manual

Pure sine wave inverter
Table of Contents

Advertisement

3.3

Display Panel Operation

This section provides information on the display panel (Figure 1-1, Item 5).
3.3.1
LED Indicators
The LED indicators on the front display panel are used to indicate the
inverter's status. Use Table 3-1 to determine the inverter status.

Table 3-1, Display Functions/Statuses

Status LED
Display LED
Green
Green
(solid)
Amber
Green
(solid)
Amber
Amber
Inverter mode. AC input is detected and the unit will
(fl ashing)
switch to By-Pass mode within 20 seconds.
Red (solid)
OFF
3.3.2
Understanding the Power and Select Buttons
A beep sound occurs every time the Power or Select button is activated (i.e.,
pressed for 1 second).
Power button – Turns the inverter On/Off during Inverter mode. Press and
hold it for 1 second to turn the inverter either ON or OFF.
Note: The Power button can be used to turn the AC output off during AC By-
Pass mode with PS4 setting—without the need to disconnect the AC input as
per the PS1 setting. See Table 3-2 or Section 3.3.3.
Select button – Used to check the inverter settings. Press the Select button
several times to scroll down to view the inverter's present setting.
© 2021 Sensata Technologies

Figure 3-1, Display Panel

Display
Function/Status
12.5
By-Pass mode. Display shows
battery voltage in DC volts.
Inverter mode. Inverter running
12.5
and display shows battery
voltage in DC volts.
0.80
Inverte) mode. Inverter is
running, and display shows
output power in kW (800W as
shown). The Select button has to
be pressed.
E01-E12
Unit has shut down. Display
shows an error code (see error
code reference chart below).
3.0 Operation