Zennio EyeZen RF ZPDEZRF868 User Manual

Knx-rf motion detector for ceiling mounting

Advertisement

Quick Links

ad
dit
io
n,
in
ca
se
of
rel
ati
vel
y
sh
ort
se
nd
ing
pe
rio
ds,
th
e
lif
eti
m
e
of
th
e
ba
tte
ry
wil
l
be
re
du
ce
d.
EyeZen RF
KNX-RF Motion detector
for ceiling mounting (868 / 915 MHz)
Application program version: [1.0]
User manual edition: [1.0]_a
ZPDEZRF868
ZPDEZRF915
www.zennio.com

Advertisement

Table of Contents
loading

Summary of Contents for Zennio EyeZen RF ZPDEZRF868

  • Page 1 EyeZen RF KNX-RF Motion detector for ceiling mounting (868 / 915 MHz) ZPDEZRF868 ZPDEZRF915 Application program version: [1.0] User manual edition: [1.0]_a www.zennio.com...
  • Page 2: Table Of Contents

    EyeZen RF ........................3 Installation ........................4 Device programming ..................... 5 Start-Up and Power Loss ....................5 Configuration......................... 6 General .......................... 6 Movement Detector ...................... 8 2.2.1 Configuration ..................... 8 2.2.2 Sendings ......................11 ANNEX I. Communication Objects....................14 https://www.zennio.com Technical Support: https://support.zennio.com...
  • Page 3: Introduction

    1 INTRODUCTION 1.1 EYEZEN RF EyeZen RF from Zennio is a device that aims the detection of movement, communicating completely wirelessly via radio frequency. This device has been designed for ceiling or false ceiling mounting by means of the bundled accessories.
  • Page 4: Installation

    To get detailed information about the technical features of this device, as well as on the installation process and on security procedures, please refer to the corresponding Datasheet, bundled with the original packaging of the device and also available at www.zennio.com. https://www.zennio.com Technical Support:...
  • Page 5: Device Programming

    During the start-up of the device, the detection notification LED flashes red for one minute before the motion sensor is ready. Furthermore, if the tamper and battery alarms are enabled, the state of these 2 alarms will be sent after each reset. https://www.zennio.com Technical Support: https://support.zennio.com...
  • Page 6: Configuration

    Transmission Power [Minimum / Medium / Maximum] : allows to set the transmission power of the device. The default values of each parameter will be highlighted in blue in this document, as follows: [default/rest of options]. https://www.zennio.com Technical Support: https://support.zennio.com...
  • Page 7 Note: the first sending after download or bus failure takes place with a delay of up to 255 seconds, to prevent bus overload. The following sending match the period set. Note: with the aim of increase the battery life, Heartbeat will only be configurable in days. https://www.zennio.com Technical Support: https://support.zennio.com...
  • Page 8: Movement Detector

    In any case, it is also possible to configure blind time to be counted from the transition from detection to no detection transition, where during this time any motion will be ignored. For a better understanding, an operational diagram of the is added. https://www.zennio.com Technical Support: https://support.zennio.com...
  • Page 9 Both the number of windows and its duration is configurable from ETS by enabling this functionality, furthermore it is possible to send additionally different HVAC modes for detection and no detection states. In addition, EyeZen RF, allows any detected motion to be notified by means of the LED detection indicator https://www.zennio.com Technical Support: https://support.zennio.com...
  • Page 10 / Enabled / Enabled during 5 minutes after reset]: activates or deactivates the LEDs that indicate motion detection. Note: Enabling this functionality may shorten battery life of the device HVAC Control [Off / On]: activates the climate system control, showing the following parameters https://www.zennio.com Technical Support: https://support.zennio.com...
  • Page 11: Sendings

    In this tab it is possible to customise the sending for Detection and No detection states, as well as, their periodicity and delay. ETS PARAMETERISATION The Sending tab contains the following parameters, which are analogous for both Detection and No Detection. https://www.zennio.com Technical Support: https://support.zennio.com...
  • Page 12 (as set in Value [1…64]) through the “Motion (Scene)” communication object. Scaling [enabled / disabled]: enables or disables the sending of a percentage value (as set in Value [0…100]) through the “Motion (Scaling)” communication object. https://www.zennio.com Technical Support: https://support.zennio.com...
  • Page 13 In addition, the shorter the sending period, the shorter the life of the battery. Delay [0…255][s/min] [0…18][h]: sets a delay between the detection state switchover and the actual sending to the bus. https://www.zennio.com Technical Support: https://support.zennio.com...
  • Page 14: Annex I. Communication Objects

    1 Byte C - - T - DPT_HVACMode Motion (HVAC) Auto, Comfort, Standby, Economy, Building Protection 3=Economy 4=Building Protection 1 Bit C - - T - DPT_Trigger [Heartbeat] Object to Send '1' Sending of '1' Periodically https://www.zennio.com Technical Support: https://support.zennio.com...
  • Page 15 Join and send us your inquiries about Zennio devices: https://support.zennio.com Zennio Avance y Tecnología S.L. C/ Río Jarama, 132. Nave P-8.11 45007 Toledo (Spain). Tel. +34 925 232 002. www.zennio.com info@zennio.com...

This manual is also suitable for:

Eyezen rf zpdezrf915

Table of Contents