Device Programming; Start-Up And Power Loss - Zennio EyeZen RF ZPDEZRF868 User Manual

Knx-rf motion detector for ceiling mounting
Table of Contents

Advertisement

EyeZen RF

1.3 DEVICE PROGRAMMING

Once the battery is connected, downloading both the physical address and the
application program will be possible. To do this, the EyeZen RF must be in "active" state.
Generally, EyeZen RF remains in a low consumption idle state in which it does not
respond to orders or reading requests, therefore, it is necessary to force it out of this idle
state in order to perform the downloading.
The EyeZen RF enters the active state and remains in the active state for 1 minute when
the programming button is pressed.
In addition, after power failure or programming the device will remain in the active state
for 10s.
Note: if the programming LED does not light up when the battery is removed and
reconnected, perform a longer power failure (at least 30 seconds).

1.4 START-UP AND POWER LOSS

During the start-up of the device, the detection notification LED flashes red for one
minute before the motion sensor is ready.
Furthermore, if the tamper and battery alarms are enabled, the state of these 2 alarms
will be sent after each reset.