Table of Contents

Advertisement

Technical Specifications

BURNER TYPE
Output
Fuel
Category
Gas flow rate
Gas pressure
Power supply
Total power consumption
Fan motor power consumption
Protection
Operation
Operating temperature
Storage Temperature
Working service (*)
Note1:
All gas flow rates are referred to Stm
(net calorific value H
Note2:
Maximum gas pressure = 360 mbar (with Dungs MBDLE)
Minimum gas pressure = see gas curves.
Note3:
Burners are suitable only for indoor operation with a maximum relative humidity of 80 %
Note4:
with electrode
The values in the diagrams refer to natural gas with a calorific value of 8125 kcal/Stm
3
0.714 kg/Stm
.
The values in the diagrams refer to GPL with a calorific value of 22300 kcal/Stm
3
Stm
. When the calorific value and the density change, the pressure values should be adjusted accordingly.
Gas categories and countries of application
GAS CATEGORY
I
2H
I
2E
I
2E( R ) B
I
2EK
I
2ELL
I
2Er
Fuel
DANGER! The burner must be used only with the fuel specified in the burner data
plate.
PART I: SPECIFICATIONS
E115X M-..
300 - 1150
min. - max. kW
32 - 122
min.- max. Stm
3
/h
min.- max. mbar
2,7
kW
2,2
kW
Progressive - Fully modulating
°C
°C
3
/ h (1.013 mbar absolute pressure, 15 °C temperature) and are valid for G20 gas
3
= 34,02 MJ / Stm
); for L.P.G. (net calorific value H
i
= 500 mbar (with Siemens VGD or Dungs MultiBloc MBE)
Where:
AT, ES, GR, SE, FI, IE, HU, IS, NO, CZ, DK, GB, IT, PT, CY, EE, LV, SI, MT, SK, BG, LT, RO, TR, CH
E150X M-..
E180X M-..
250 - 1550
320 - 1800
Natural gas
(see next paragraph)
26 - 164
34 - 190
(see Note 2)
230V 3~ / 400V 3N ~ 50Hz
2,7
3,5
2,2
3,0
IP40
-10 ÷ +50
-20 ÷ +60
Intermittent
= 93,5 MJ / Stm
i
3
(15°C, 1013 mbar) and a density of 2.14 kg/
Natural gas pressure shown in diagram
Real gas pressure
Natural gas flow rate shown in diagram
Real gas flow rate
Natural gas density shown in diagram
Real gas density
COUNTRY
LU, PL
BE
NL
DE
FR
7
E115X L-..
E150X L-..
300 - 1150
250 - 1550
L -
LPG
I
3B/P
11,2 - 43
9,3 - 58
(see Note 2)
230V 3~ / 400V 3N ~ 50Hz
2,7
2,7
2,2
2,2
IP40
Progressive - Fully modulating
-10 ÷ +50
-20 ÷ +60
Intermittent
3
)
3
(15°C, 1013 mbar) and a density of
Type
--
Model
--
Year
--
S.Number
--
Output
--
Oil Flow
--
Fuel
--
Category
--
Gas Pressure
--
Viscosity
--
El.Supply
--
El.Consump.
--
E180X L-..
320 - 1800
11,9 - 67
3,5
3,0

Advertisement

Table of Contents
loading

This manual is also suitable for:

E150xE180x

Table of Contents