Transport and storage
If the product must be stored, avoid humid and corrosive places. Observe the temperatures stated in the burner data table at the begin-
ning of this manual. The packages containing the burners must be locked inside the means of transport in such a way as to guarantee
the absence of dangerous movements and avoid any possible damage.
In case of storage, the burners must be stored inside their packaging, in storerooms protected from the weather. Avoid humid or corro-
sive places and respect the temperatures indicated in the burner data table at the beginning of this manual.
Packing
Burners are despatched in cardboard packages whose dimensions are:
1636mm x 1036mm x 1016mm (L x P x H).
Packing cases of this type are affected by humidity and are not suitable for stacking.
The following are placed in each packing case:
burner with detached gas train;
gasket or ceramic fibre plait (according to burner type) to be inserted between the burner
and the boiler;
(if provided) detection photoelement deatached from the burner
envelope containing this manual and other documents.
To get rid of the burner's packing, follow the procedures laid down by current laws on disposal
of materials.
Handling the burner
The burner is designed to work positioned according to the picture below. For different installations, please contact the Manufacture.
Warning! Don't lift the burner by the air intake silencer!
The burner is provided with eyebolts, for handling operations and it can be lifted with a hydraulic lift or a small manual crane. (A)
The burner is mounted on a stirrup provided for handling the burner by means of a fork lift truck: the forks must be inserted into the A
anb B ways. Remove the stirrup only once the burner is installed to the boiler.