Technical Specifications

BURNER TYPE
Output
Fuel
Category
Gas rate- Natural gas
Light oil rate
Oil viscosity
Gas pressure
Power supply
Total power consumption
Electric motor
Pump motor (Cucchi)
Protection
Operation
Valves size / Gas connection
Gas train 50
Valves size / Gas connection
Gas train 65
Valves size / Gas connection
Gas train 80
Valves size / Gas connection
Gas train 100
Operating temperature
Storage Temperature
Working service
Note1:
All gas flow rates are referred to Stm
(net calorific value H
Note2:
Maximum gas pressure = 500mbar (with Siemens VGD or Dungs MultiBloc MBE)
Minimum gas pressure = see gas curves.
Note3:
Burners are suitable only for indoor operation with a maximum relative humidity of 80 %
Country and usefulness gas categories
GAS
CATEGORY
I
AT
ES GR SE
2H
I
LU
PL
2E
I
BE
-
2E( R ) B
(*) I
NL
-
2EK
I
DE
-
2ELL
I
FR
-
2Er
(*) Only for I
: the appliance was configured for the appliance category K (I2K) and is suitable for the use of G and G+ distribution gases according to the specifications as
2EK
included in the NTA 8837:2012 Annex D with a Wobbe index of 43.46 – 45.3 MJ/m3 (dry, 0 °C, upper value) or 41.23 – 42.98 (dry, 15 °C, upper value). This appliance can
moreover be converted and/or be calibrated for the appliance category E (I2E). This therefore implies that the appliance "is suitable for G+ gas and H gas or is demonstrably
suitable for G+ gas and can demonstrably be made suitable for H gas" within the meaning of the "Dutch Decree of 10 May 2016 regarding amendment of the Dutch Gas
Appliances Decree and the Dutch Commodities (Administrative Fines) Act in connection with the changing composition of gas in the Netherlands as well as technical
amendment of some other decrees.
Fuel
DANGER! The burner must be used only with the fuel specified in the burner data
plate.
HRX92R-FGR
min. - max. kW
3
min.- max. (Stm
/h)
min. - max. kg/h
cSt @ 40 °C
mbar
kW
kW
kW
100 / DN100
°C
°C
3
/h (1.013 mbar absolute pressure, 15° C temperature) and are valid for G20 gas
3
= 34.02 MJ / Stm
i
FI
IE
HU
IS
NO CZ DK GB
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HRX92-FGR
320 - 1870
680 - 2504
(
55 - 198
72 - 265
44 - 158
57 - 211
9,1
9,1
7,5
7,5
1,1
1,1
Progressive - Fully modulating
50 / Rp2
50 / Rp2
65 / DN65
65 / DN65
80 / DN80
80 / DN80
100 / DN100
);
COUNTRY
IT
PT CY EE LV
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
6
HRX512-FGR
HRX515-FGR
1280 - 3600
1.065 - 4160
Natural gas / light oil
see next paragraph
)
135 - 381
113 - 440
108 - 304
90 - 351
2 - 7,4
see Note 2
(
)
400V 3N ~ 50Hz ac
12,6
17,5
11,0
15,5
1,1
1,5
IP40
50 / Rp2
50 / Rp2
65 / DN65
65 / DN65
80 / DN80
80 / DN80
100 / DN100
100 / DN100
-10 ÷ +50
-20 ÷ +60
Continuous
SI
MT SK BG LT RO TR CH
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Type
Model
Year
S.Number
Output
Oil Flow
Fuel
Category
Gas Pressure
Viscosity
El.Supply
El.Consump.
HRX520-FGR
1600 - 4816
169 - 510
135 - 406
17
15
1,5
50 / Rp2
65 / DN65
80 / DN80
100 / DN100
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
--
--
--
--
--
--
--
--
--
--
--
--