Encoder Interface - Photon Focus Gpixel MV8 Series User Manual

Table of Contents

Advertisement

13.7.4 Encoder Interface

Fig. 13.7 and Fig. 13.8 show, how differential and single ended encoder must be connected to
the GigE camera's I/O interface. Encoder A and B singals must be connected to LineIn0 and
LineIn1. They can be connected in either way, as long as the encoder is configured accordingly
Section C.5.
If available on the encoder, the Z signal must be connected to LineIn2 and the Y/ALARM to
LineIn3.
The EncoderAlarmMode of the encoder configuration must be set to True in order
to use the alarm indication.
Consider the polarity of the encoders Y/ALARM signal. The LineIn3 must be in-
verted, when the Y/ALARM signal is low active.
The Z signal is a single pulse that occurs once every shaft encoder rotation. It can
be used to reset the encoder (Section 6.4).
Figure 13.7: Connection of a differential encoder
.
MAN094 02/2022 V1.1
17-pin M12
I/O Connector
Encoder
RS422 or D-HTL
3
A
ISO_INC0
4
5
B
ISO_INC1
6
7
Z
ISO_INC2
8
TTL120
ALARM
ISO_IN3
9
Y
GND
17
YOUR_GND
Isolator
C0
LineIn0
R0
C1
LineIn1
R1
C2
LineIn2
R2
10nF
LineIn3
120
¡
ISO_GND
13.7.4 Encoder Interface
Camera
105 of 141