Cleaning protocol

Warning

You must read the installation instructions, technical
instructions, and instructions for use before
handling this equipment. The instrument must be
used only for the specifi c purpose for which it is
designed, and which is described in our literature.
The assembly and connection to the mains must be
carried out by qualifi ed personnel.
Any modification of the DM without the manufacturer's written authorisation
is prohibited.
Caution
Only those accessories allowed and provided by Midmark Europe for this DM
may be used.

General maintenance

Apart from regular cleaning, our products do not
require regular maintenance.
The mechanical parts used as blocking mechanisms
(smooth arch, notched arch, ratchet mechanisms,
etc.) do not require any specific attention. The gas
springs on tables do not require any maintenance.
Their shaft must be kept clean, must not be subject
to jolts or hard knocks, and must not be cleaned with
any corrosive products. The electric and hydraulic
jacks do not require any particular attention.

Disinfection

This Medical Device must be regularly disinfected by products which qualify as Bactericides, Virucides and
Fungicides.

Maintenance Instructions

Painted surfaces (epoxy polyester fi nish)
The use of ordinary cleaning products, eg. window cleaning products, is perfectly suitable for cleaning
surfaces fi nished in epoxy polyester. The following products are not recommended as they will damage
these surface :
Petrol
– Solvants :
High-grade alcohols :
– Aliphatics
– Aromatics
Ketones - esters
Tri -perchlorethylene
User's Guide
All manuals and user guides at all-guides.com
– Bases :
– Acids :
Under no circumstances must electrical parts
(motor, unit housing the electrical control systems,
control unit, adaptor etc.) be opened. MIDMARK
EUROPE cannot be held responsible for any
damage resulting from the instructions not being
followed.
The variable height tables, chairs and trolleys are
equipped either :
– With arms fi tted with self lubricating
articulation rings.
– With telescopic bearing runners. In this
case they should be lubricated once a
year (particularly if the runners are noisy)
with ordinary grease. (See the exploded
drawings for access to the runners).
10 % sodium
– Others :
10 % ammonium
30 % nitric
30 % chlorhydric
10 % citric
Bleach
Abrasive powders
Any abrasive
Cleaning product