promotal iQuest 3055-20 User Manual

promotal iQuest 3055-20 User Manual

Electric examination couch
Table of Contents

Advertisement

Quick Links

User's Guide
Model Shown : 3050-40
Electric Examination Couch
3055-20

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the iQuest 3055-20 and is the answer not in the manual?

Questions and answers

Summary of Contents for promotal iQuest 3055-20

  • Page 1 User’s Guide Model Shown : 3050-40 Electric Examination Couch 3055-20...
  • Page 2 Operating Manual are deemed correct at the time of 22, rue de Saint-Denis de Gastines printing. B.P. 26 - 53500 ERNÉE Cedex Promotal , however, reserves the right to modify its models FRANCE and its procedures or render them obsolete without notice. Tél. :...
  • Page 3: Table Of Contents

    Summary Important information Safety symbols Applied parts Electromagnetic interference Unpacking precautions Medical device delivered on a wooden pallet Storage conditions Conditions of use Unpacking and Installation Step by step Check Remark: Authorised EC Representative Cleaning protocol Warning Cleaning/Disinfecting User manual – iQuest Intended purpose Patient weight capacity Protection against penetration of liquids...
  • Page 4 Summary (reference 2536) Pair of stirrups (reference 850) Installing the stirrups Pair of legrests (reference 840) Installing the legrests Pair of covers for legrests 2 hook IV pole (reference 985-01) Installing the IV pole Auto-blocking I.V. pole (reference 2985-01) Installing the IV pole Adjusting the height of the IV pole Head rest Installing the head rest...
  • Page 5 Options Accumulator (reference 3092-01) Charging the accumulator Accumulator safety symbols Technical characteristics of the accumulator Circuit breaker (reference 3058-01) Using the circuit breaker Reel for electric cable (reference 3032-01) Supplemental power socket (reference 30400-01) Using the supplemental power socket Equipotential terminal (reference 2059-01) Notes Lifespan of the Medical Device...
  • Page 6: Important Information

    Important information Safety symbols Warning sign Information marked with this symbol must be read and strictly complied with! Remark Draws your attention to a procedure, practice or situation. Maximum number of Correct orientation for Humidity limitation stacked pallets transportation Atmospheric pressure Temperature Fragile limitation...
  • Page 7: Applied Parts

    Electromagnetic interference This Promotal medical device was designed and built to minimize electromagnetic interference with other equipment. If interference is, however, observed, you must remove the apparatus causing the interference from the room and/or plug it into an isolated circuit.
  • Page 8: Unpacking Precautions

    Unpacking precautions Medical device delivered on a wooden pallet The medical device positioned on a wooden pallet ensure that the forklift truck is correctly positioned may be easily moved using a forklift truck, as long in relation to the pallet, and that the unit is stable. as this is used correctly.
  • Page 9: Check

    2) Check the external components for any Remark: Authorised EC Representative Within the European Union, all problems, complaints or questions should be addressed to the Authorised EC Representative of Promotal indicated below: Promotal 22, rue de Saint-Denis de Gastines 53500 Ernée,...
  • Page 10: Cleaning Protocol

    • The use of abrasive powders or any other abrasive product should be avoided. • High-pressure cleaning is forbidden. Under no circumstances shall Promotal be held liable under warranty for any damage caused by non-compliance with the use instructions for a detergent- disinfectant.
  • Page 11: User Manual - Iquest

    User manual – iQuest Intended purpose This medical device is designed for use in professional premises only: • Medical office • Health establishment This medical device must not be installed in domestic premises. This medical device is intended for general or specialist medical examinations and acts. Only health professionals (doctors, caregivers) and/or qualified members of the technical staff can handle or use the device.
  • Page 12: Electrical Connection

    User manual – iQuest Electrical connection This medical device must be connected to the mains supply. • Connection to the mains supply : 120 V or 230 V (depending on the country) • Frequency : 50/60 Hz • Protection classification : Class 1/ type B device •...
  • Page 13: Safety

    Safety Caution To avoid malfunctions and for safety reasons, no objects must be left under the chair’s seat or between its moving frames. Caution the supply cable for this medical device may represent an obstacle and cause falls. Do not forget its presence when moving around the device once connected to the mains supply.
  • Page 14 Safety note Before using the medical device lowering control, ensure that no objects or obstacles are between the moving parts and the ground. Safety note When using the position memory function, movements can be interrupted by pushing on one of the command buttons for the couch or, as a last resort, by disconnecting the power supply cord.
  • Page 15: Using The Individual Control

    Using the individual control Manual command Presentation Safety note When using the pre-programmed positions, (welcome, QE1, QE2, chair position, couch position), do not leave the patient on the couch without supervision. Default position Standard position for getting into and out of the couch (H: 47cm) at the touch of a button (push) NB: This position cannot be altered...
  • Page 16: Adjusting The Height

    Using the individual control Adjusting the height The position below is obtained by pressing on the manual control. Down Adjusting the trendelenburg position The position below is obtained by pressing on the manual control. Down User’s Guide...
  • Page 17: Adjusting The Backrest Tilt

    Adjusting the backrest tilt The position below is obtained by pressing on the manual control. Down Position QE1 et QE2 The QE1 and QE2 buttons are factory-set but cannot be modified. To enter a new position for buttons QE1 and QE2, simply adjust the couch to the desired position and then press and hold the QE1 (or QE2) button for 6 seconds.
  • Page 18: Welcome Position

    Welcome position The position can be recalled by pressing once on the button NB: This position cannot be modified. Welcome position Placing on castors (standard for model 3050-50) Safety note This position can be recalled by pressing and Unplug the power supply cable holding the button before moving the MD.
  • Page 19: Using The Couch

    Using the Couch Paper roll Installation of the paper roll holder Using the paper roll Caution follow the indications provided well obtain a greater Cover the upholstery with paper before use. longevity of the material. User’s Guide...
  • Page 20: Accessories

    Accessories Only accessories designed and provided by Promotal for this medical device are authorised for use. Pair of Clamps (reference 166) Installing the Clamps Take the stopper (B) out of the square tube if necessary. Loosen the nuts (V), and put the pair of clamps ref.166 (E) into position in the square tubes.
  • Page 21: Pair Of Stirrups

    Pair of stirrups (reference 850) Installing the stirrups Ensures good clamping with each Caution Clamps are necessary to install these accessories. (réf. : 166) Pair of legrests (reference 840) Installing the legrests Caution Clamps are necessary to install these accessories. Ensures good clamping with each (réf.
  • Page 22: Hook Iv Pole

    Accessories Only accessories designed and provided by Promotal for this medical device are authorised for use. 2 hook IV pole Caution (reference 985-01) Clamps are necessary to install these accessories. Installing the IV pole (réf. : 166) Ensures good clamping with each Auto-blocking I.V.
  • Page 23: Head Rest

    Head rest (reference 30679-01) Installing the head rest Positioning Push the head rest's band insert into the plate fixed to the back rest. Adjustment Just press on the head rest to lower it (D), or pull on the band insert to raise it (R). User’s Guide...
  • Page 24: Adjustable Paper-Roll Holder

    Accessories Only accessories designed and provided by Promotal for this medical device are authorised for use. Adjustable paper-roll holder (reference 2056-02) Installating the paper roll holder M6x25 (x 2) N°4 Allen key User’s Guide...
  • Page 25: Installation Of The Paper Roll

    Installation of the paper roll The paper roll is positioned on a mobile axis with adjustable hooks at each end. 1. Unscrew the screw handle (VS). 2. To remove the paper roll holder 1/2 slightly (PR). 3. Insert the paper roll. Cover the upholstery with paper before use.
  • Page 26: Vise

    Accessoires Only accessories designed and provided by Promotal for this medical device are authorised for use. Vise (reference 878-12) Caution Mounting this accessory requires the use of rails (reference 30878-65 P or T, 30878-75 P or T, 30878-85 P or T)
  • Page 27: Crystal Head Section Side Protectors

    Crystal head section side protectors (reference 3056-02) Cruciform screw driver Positioning the protector 1. Fixer les boutons pressions à l’emplacement prévu à l’arrière de la têtière. 2. Clipser les boutons pressions. 3. Positionner la protection sur la sellerie au niveau de la tête.
  • Page 28: Foot Pedal

    Accessoires Only accessories designed and provided by Promotal for this medical device are authorised for use. Foot pedal Presentation Safety note When using the pre-programmed positions, (welcome and QE1, QE2), do not leave the patient on the couch without supervision.
  • Page 29: Setting Up The Control Unit

    Setting up the control unit User’s Guide...
  • Page 30: Options

    Options Accumulator (reference 3092-01) (Built in to the device’s power supply system) (Note: the couch can functions the same in «Battery mode» or in «Mains mode». Charging the accumulator Before using the chair for the 1st time, it is recommended to leave it plugged into the mains for 24 hours to enable the accumulator to charge fully.
  • Page 31: Circuit Breaker

    Circuit breaker (reference 3058-01) Using the circuit breaker Withdraw the key to completely immobilise the Re-insert the key to use the couch again. couch. Reel for electric cable (reference 3032-01) Leaving the cable Arranging the cable User’s Guide...
  • Page 32: Supplemental Power Socket

    Options Supplemental power socket (reference 30400-01) Available exclusively and standard EU & UK Safety note When a medical device is connected to the supplemental power socket, the system becomes an medical electrical device in accordance with Standard EN 60601-1. It is the responsibility of the user to ensure compliance of the medical electrical system with standard EN 60601-1 (Article 16) Using the supplemental power socket...
  • Page 33: Equipotential Terminal

    Equipotential terminal (reference 2059-01) Ce dispositif médical est de classe électrique 1. Il doit être raccordé uniquement à un réseau d’alimentation équipé d’une terre de protection. Remark the equipotential terminal allows the connection of an equipotential conductor to bring all the different elements of an electro-medical system to the same potential.
  • Page 34: Notes

    Notes User’s Guide...
  • Page 35 Notes User’s Guide...
  • Page 36: Lifespan Of The Medical Device

    Medical device end of service life Your dealer is responsible for the recovery and end of life treatment of this device. If necessary, do not hesitate to contact Promotal. We can propose solutions to treat this equipment in the best conditions.
  • Page 37: Maintenance Notebook

    Maintenance notebook User’s Guide...
  • Page 38: Warranty Information

    No Authorization No person or fi rm is authorized to create for Promotal any other obligation or liability in connection with the products. THIS WARRANTY IS PROMOTAL’S ONLY WARRANTY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
  • Page 39 22, rue de Saint-Denis de Gastines, 53500 Ernée - FRANCE Tél. : +33 (0)2 43 05 17 76, Fax : + 33 (0)2 43 05 72 00, www.promotal.com S.A.S. au capital de 4 290 660 € - R.C.S. LAVAL Siret 421 156 720 00011 - TVA FR 67 421 156 720 - APE 3250A...
  • Page 40 PROMOTAL - FRANCE www.promotal.com DIC3055-20_2318EN...

Table of Contents