38 Program features

Adaptive programming

Conventionally, the user can control the operation of the drive by parameters.
However, the standard parameters have a fixed set of choices or a setting
range. To further customize the operation of the drive, an adaptive program can
be constructed out of a set of function blocks.
The Drive Composer PC tool V2.7 and above (available separately) has an
Adaptive programming feature with a graphical user interface for building the
custom program. The function blocks include the usual arithmetic and logical
functions, as well as, for example, selection, comparison and timer blocks.
The physical inputs, drive status information, actual values, constants and
parameters can be used as the input for the program. The output of the
program can be used, for example, as a start signal, external event or reference,
or connected to the drive outputs. See the table below for a listing of the
available inputs and outputs.
If you connect the output of the adaptive program to a selection parameter that
is a pointer parameter, the selection parameter will be write-protected.
Example:
If parameter
31.01 External event 1 source
programming block output, the parameter value is shown as Adaptive program
on a control panel or PC tool. The parameter is write-protected (= the selection
cannot be changed).
The status of the adaptive program is shown by parameter
status. The adaptive program can be disabled by
program
program.
For more information, see the
(3AXD50000028574 [English].
Inputs available to the adaptive program
Input
I/O
DI1
DI2
DI3
DI4
DI5
DI6
AI1
AI2
Actual signals
Motor speed
Output frequency
Motor current
Adaptive programming application guide
Source
10.02 DI delayed status
status, bit 1
10.02 DI delayed
status, bit 2
10.02 DI delayed
status, bit 3
10.02 DI delayed
status, bit 4
10.02 DI delayed
status, bit 5
10.02 DI delayed
12.11 AI1 actual value
12.21 AI2 actual value
01.01 Motor speed used
01.06 Output frequency
01.07 Motor current
is connected to an adaptive
96.70 Disable adaptive
,
bit 0
07.30 Adaptive

Advertisement

Table of Contents
loading