No.
Name/Value
51.33
FBA A appl SW
ver
0x0000...0xffff
52
52 FBA A data in
52.01
FBA A data in1
None
CW 16bit
Ref1 16bit
Ref2 16bit
SW 16bit
Act1 16bit
Act2 16bit
CW 32bit
Ref1 32bit
Ref2 32bit
SW 32bit
Act1 32bit
Act2 32bit
SW2 16bit
Description
Shows application program revision of the
adapter module in format axyz, where a = major
revision number, xy = minor revision number, z =
correction number or letter.
Example: 190A = revision 1.90A.
Application program version of adapter module.
Selection of data to be transferred from drive to
fieldbus controller through fieldbus adapter A.
Note: 32-bit values require two consecutive
parameters. Whenever a 32-bit value is selected
in a data parameter, the next parameter is
automatically reserved.
Parameters
52.01...52.12
transferred from the drive to the fieldbus
controller through fieldbus adapter A.
None.
Control Word (16 bits)
Reference REF1 (16 bits)
Reference REF2 (16 bits)
Status Word (16 bits)
Actual value ACT1 (16 bits)
Actual value ACT2 (16 bits)
Control Word (32 bits)
Reference REF1 (32 bits)
Reference REF2 (32 bits)
Status Word (32 bits)
Actual value ACT1 (32 bits)
Actual value ACT2 (32 bits)
Status Word 2 (16 bits)
Parameters 215
select data to be
Def/
FbEq16
0x0000
-
None
0
1
2
3
4
5
6
11
12
13
14
15
16
24