The printer is initialized upon power supply. The printer then starts warming-up
and the Heater Lamp lights. The temperature is controlled as follows.
Mode 1
The temperature is controlled to maintain 115°C during standby and 195°C during
printing. If this mode continues for 90 seconds, it will shift to mode 2.
Mode 2
The temperature of the Heat Roller falls gradually to about 185°C from about
195°C.
If this mode continues for 208 seconds, it will shift to mode 3.
Mode 3
The temperature is controlled to maintain 115×C during standby and 185×C
during printing. Unless an error occurs or a top cover is opened, this mode is
maintained.
Warming-Up
195°C
185°C
115°C
The state before
discontinuation of
temperature control
Mode 1,
warming-up
Mode 2, 3 or Power
OFF
Mode 1: 90sec Mode 2: 208sec
Temperature immediately after temperature control start
50°C or more, less
less than 50°C
than 115 °C
Mode 1
Mode 1
Mode 2
41
Thermistor detecting temperature
Printing
Mode 3
115°C or more
Mode 3
Standby