D M X S E T U P
DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used as a form of
communication between intelligent fixtures and controllers. A DMX controller sends DMX data
instructions from the controller to the fixture. DMX data is sent as serial data that travels from fixture to
fixture via the DATA "IN" and DATA "OUT" XLR terminals located on all DMX fixtures (most controllers
only have a DATA "OUT" terminal).
DMX Linking: DMX is a language allowing all makes and models of different manufactures to be linked
together and operate from a single controller if all fixtures and the controller are DMX compliant. To
ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable
path possible. The order in which fixtures are connected in a DMX line does not influence the DMX
addressing. For example, a fixture assigned a DMX address of 1 may be placed anywhere in a DMX
line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a DMX address
of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is
in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX Operation): This
fixture can be controlled via DMX-512 protocol. The DMX address is set
using the control panel. Your unit and your DMX controller require a 5-pin
XLR connector for data input and data output. We recommend Accu-Cable
DMX cables. If you are making your own cables, be sure to use standard
110-120 Ohm shielded cable (This cable may be purchased at almost all
pro lighting stores). Your cables should be made with a male and female
XLR connector on either end of the cable. Also remember that DMX cable
must be daisy chained and cannot be split.
5-Pin XLR DMX Connectors: This fixture uses 5-pin DMX-512 data cables for DATA transmission in
place of a 3-pin. 5-pin DMX fixtures may be implemented in a 3-pin DMX line. When inserting standard
5-pin data cables in to a 3-pin line a cable adapter must be used, these adapters are readily available
at most electric stores. The chart below details a proper cable conversion.
Note: Do not connect the cable's shield conductor to the ground lug, or allow the shield conductor
to contact the XLR's outer casing. Grounding the shield could cause a short circuit.