UID (Unit Identifier)/BMC Reset Switch and UID/BMC Reset LED Indicators
A UID / BMC Reset switch (JUIDB1) is located on the rear of the motherboard. This switch
has dual functions. It can be used to identify a system unit that is in need of service, and it
can also be used to reset the BMC settings.
When functioning as a BMC reset switch, JUIDB1 will trigger a cold reboot when you press
and hold the switch for six seconds. It will also restore the BMC to the manufacturer's default
when you press and hold the switch for 12 seconds.
When functioning as a UID LED switch, JUIDB1 will turn both rear UID LED (LED4) and front
UID LED (Pin 7/Pin 8 of JF1) on and off when you press the switch on/off.
To achieve these dual purposes, the UID LED/BMC Reset switch works in conjunction with
the BMC Heartbeat LED (BMC LED) and front/rear UID LEDs. Please note that UID can
also be triggered via BMC on the motherboard. For more details on the UID LEDs and BMC
LEDs, refer to the tables on next page. Also, refer to the BMC User'd Guide posted on our
website at
http://www.supermicro.com
When Used as a UID LED Switch
Rear UID LED (LED4) & Front UID LED
(JF1: Pins 7& 8)
Rear UID LED
UID-LED
Front UID LED
Puns 7 & 8 (JF1)
Press the switch (JUIDB1) to turn on and off both rear
and front UID LED indicators.
for more information on BMC.
UID/BMC Reset Switch (JUIDB1)
Features & Settings
Blue: Unit identified BMC Heartbeat LED
Blue: Unit identified
BMC Reset: Press
& hold the switch
(JUIDB1) 6 seconds
BMC Reset: Press
& hold the switch
(JUIDB1) 12 seconds
UID/BMC Reset Switch (JUIDB1)
Pin Definitions
Pin#
Definition
1
Ground
2
Ground
3
Button In
4
Button In
61
Chapter 4: Motherboard Connections
BMC Heartbeat LED (LEDBMC)
BMC Heartbeat LED (LEDBMC)
Green Blinking:
LEDBMC
BMC Normal
LEDBMC: Solid green: during reboot
Triggering a cold reboot;
LED: solid green on during cold reboot
LEDBMC: Solid green: during BMC reset
BMC: Reset to the manufacturer's default;
LED solid on during BMC Reset