Dallas Semiconductor MAXIM DS3112 Manual page 81

Tempe t3/e3 multiplexer 3.3v t3/e3 framer and m13/e13/g.747 mux
Table of Contents

Advertisement

Bits 8 to 11: Repetitive Pattern Length Bits 5 (RPL0 to RPL3). RPL0 is the LSB and RPL3 is the MSB of a
nibble that describes the how long the repetitive pattern is. The valid range is 17 (0000) to 32 (1111). These bits are
ignored if the receive BERT is programmed for a pseudorandom pattern. To create repetitive patterns less than 17
bits in length, the user must set the length to an integer number of the desired length that is less than or equal to 32.
For example, to create a 6-bit pattern, the user can set the length to 18 (0001) or to 24 (0111) or to 30 (1101).
Repetitive Pattern Length Map
Length
Code
17 Bits
0000
21 Bits
0100
25 Bits
1000
29 Bits
1100
Bit 13: Interrupt Enable for Counter Overflow (IEOF). Allows the receive BERT to cause an interrupt if either
the Bit Counter or the Error Counter overflows (
0 = interrupt masked
1 = interrupt enabled
Bit 14: Interrupt Enable for Bit Error Detected (IEBED). Allows the receive BERT to cause an interrupt if a bit
error is detected
(Figure
0 = interrupt masked
1 = interrupt enabled
Bit 15: Interrupt Enable for Change of Synchronization Status (IESYNC). Allows the receive BERT to cause
an interrupt if there is a change of state in the synchronization status (i.e., the receive BERT either goes into or out
of synchronization) (
Figure 8-1
0 = interrupt masked
1 = interrupt enabled
Length
Code
18 Bits
0001
22 Bits
0101
26 Bits
1001
30 Bits
1101
8-1).
).
Length
19 Bits
23 Bits
27 Bits
31 Bits
Figure 8-1
).
81 of 133
Code
Length
0010
20 Bits
0110
24 Bits
1010
28 Bits
1101
32 Bits
DS3112
Code
0011
0111
1011
1111

Advertisement

Table of Contents
loading

This manual is also suitable for:

Maxim ds3112+Maxim ds3112n

Table of Contents