Download Print this page
Hytronik HMW32 Manual

Hytronik HMW32 Manual

Ip65 high bay hf motion sensor

Advertisement

Quick Links

IP65 High Bay HF Motion Sensor
HMW32
Daylight Harvest with Remote Control
Technical Data
Input Characteristics
Model No.
Mains voltage
Stand-by power
Load ratings:
Capacitive
400VA@120V; 800VA@220 -277V
Resistive
800W@120V; 1600W@220 -277V
Warming-up
Safety and EMC
EMC standard (EMC)
Safety standard (LVD)
Radio Equipment (RED)
Certi cation
Mechanical Structures and Installations
For more details, please refer to user manual.
A. Ceiling mount
Subject to change without notice.
HF
HMW32
120~277VAC 50/60Hz
<1W
20s
EN55015, EN61000
EN60669-1, EN60669-2-1
EN300440, EN301489-1,
EN62479
Semko, CB, CE , EMC, RED, RCM
LED indicator
Photocell
Sensor module
Installation rack
Sensor Data
Model No.
Sensor principle
Operation frequency
Transmission power
Detection range
Detection angle
Environment
Operation temperature
IP rating
RED
Rotary switch
Infrared receiver
Cable entry
Edition: 26 Feb. 2020
HMW32
High Frequency (microwave)
5.8GHz +/- 75MHz
<0.2mW
Installation Height : 20m (forklift)
15m (person)
Detection Range (Ø) :20m
360
O
O
O
Ta: -20
C ~ +50
C
IP65
IP65
4.1
66.6
81.5
Ver. A0
Page 1/6

Advertisement

loading
Need help?

Need help?

Do you have a question about the HMW32 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hytronik HMW32

  • Page 1 IP65 High Bay HF Motion Sensor HMW32 Daylight Harvest with Remote Control Technical Data Input Characteristics Sensor Data Model No. HMW32 Model No. HMW32 Sensor principle High Frequency (microwave) Mains voltage 120~277VAC 50/60Hz Stand-by power <1W Operation frequency 5.8GHz +/- 75MHz...
  • Page 2: Functions And Features

    B. Screw to the Luminaire by conduit 59.6 0.825” Rotary switch LED indicator Infrared receiver Photocell Cable entry 66.6 89.9 Sensor module C. Attach to the shade by clamp Rotary switch LED indicator Infrared receiver Photocell Angle adjustment 28.5 Luminaire clamp 59.6 66.6 163.2...
  • Page 3 Daylight Harvest Light will not switch on The light switches on The light turns on at full or dims to maintain the lux level. The light output when natural light is automatically with regulates accroding to the level of natural light available. suf cient, even there is presence when natural motion detected.
  • Page 4 Settings (Remote Control HRC-11) Permanent ON/OFF function Press button “ON/OFF” to select permanent ON or permanent OFF mode. * Press button “AUTO”, “RESET” to quit this mode. The mode will change to AUTO Mode after power failure. Reset Settings Press button “RESET”, all settings go back to rotary switch settings. Shift Button Press button “Shift”, the LED on the top left corner is on to indicate mode selection.
  • Page 5: Detection Pattern

    2. The xture will go into sensor mode after the measurement, all sensor settings remain unchanged. Dual tech & RF mode All buttons are disabled. Wiring Diagram Detection Pattern Brown Blue Grey LED driver Black 1-10V+ 1-10V HMW32 (forklift) Subject to change without notice. Edition: 26 Feb. 2020 Ver. A0 Page 5/6...
  • Page 6 Additional Information / Documents 1. Regarding precautions for microwave sensor installation and operation, please kindly refer to www.hytronik.com/download ->knowledge ->Microwave Sensors - Precautions for Product Installation and Operation 2. Regarding Hytronik standard guarantee policy, please refer to www.hytronik.com/download ->knowledge ->Hytronik Standard Guarantee Policy Subject to change without notice.