SICK DC12-24V Operating Instructions Manual

SICK DC12-24V Operating Instructions Manual

2d machine vision

Advertisement

Quick Links

O P E R A T I N G I N S T R U C T I O N S
picoCam2
2D machine vision

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DC12-24V and is the answer not in the manual?

Questions and answers

Summary of Contents for SICK DC12-24V

  • Page 1 O P E R A T I N G I N S T R U C T I O N S picoCam2 2D machine vision...
  • Page 2 This work is protected by copyright. Any rights derived from the copyright shall be reserved for SICK AG. Reproduction of this document or parts of this document is only permissible within the limits of the legal determination of Copyright Law. Any modi‐...
  • Page 3: Table Of Contents

    Mounting instructions................Mounting the device................. Electrical installation................ 13 Wiring instructions..................Prerequisites for safe operation of the device........Connecting the device electrically............Operation.................... 16 Operation using SICK Vision Suite............Maintenance..................17 Maintenance plan..................Cleaning..................... Troubleshooting................. 18 General faults, warnings, and errors............Repairs......................
  • Page 4 12.1 Declarations of conformity and certificates..........12.2 Copyright notices..................O P E R A T I N G I N S T R U C T I O N S | picoCam2 8025786/1HXT/2022-11 | SICK Subject to change without notice...
  • Page 5: About This Document

    … highlights useful tips and recommendations as well as information for efficient and trouble-free operation. 8025786/1HXT/2022-11 | SICK O P E R A T I N G I N S T R U C T I O N S | picoCam2...
  • Page 6: Further Information

    Other publications related to the devices described here • Publications dealing with accessories O P E R A T I N G I N S T R U C T I O N S | picoCam2 8025786/1HXT/2022-11 | SICK Subject to change without notice...
  • Page 7: Safety Information

    It is designed for use in industrial environments. SICK AG assumes no liability for losses or damage arising from the use of the product, either directly or indirectly. This applies in particular to use of the product that does not conform to its intended purpose and is not described in this documentation.
  • Page 8: Cybersecurity

    The measures implemented in this product can only support protection against cybersecurity threats if the product is used as part of such a concept. You will find further information at www.sick.com/psirt, e.g.: • General information on cybersecurity •...
  • Page 9 Install the grounding for the product and the system in accordance with national ■ and regional regulations. 8025786/1HXT/2022-11 | SICK O P E R A T I N G I N S T R U C T I O N S | picoCam2 Subject to change without notice...
  • Page 10: Product Description

    Device open LED lights up red No firmware loaded O P E R A T I N G I N S T R U C T I O N S | picoCam2 8025786/1HXT/2022-11 | SICK Subject to change without notice...
  • Page 11: Transport And Storage

    For storage periods of longer than 3 months, check the general condition of all components and packaging on a regular basis. 8025786/1HXT/2022-11 | SICK O P E R A T I N G I N S T R U C T I O N S | picoCam2...
  • Page 12: Mounting

    Align the device so that the desired object is recorded. O P E R A T I N G I N S T R U C T I O N S | picoCam2 8025786/1HXT/2022-11 | SICK Subject to change without notice...
  • Page 13: Electrical Installation

    This is achieved by complying with the following conditions: 8025786/1HXT/2022-11 | SICK O P E R A T I N G I N S T R U C T I O N S | picoCam2 Subject to change without notice...
  • Page 14: Connecting The Device Electrically

    Ensure the voltage supply is not connected. Connect the device according to the connection diagram. O P E R A T I N G I N S T R U C T I O N S | picoCam2 8025786/1HXT/2022-11 | SICK Subject to change without notice...
  • Page 15 Trigger input, with optocoupler (+) Supply voltage input (V) 12-24 V 8025786/1HXT/2022-11 | SICK O P E R A T I N G I N S T R U C T I O N S | picoCam2 Subject to change without notice...
  • Page 16: Operation

    OPERATION Operation Operation using SICK Vision Suite The SICK Vision Suite software can be used to parameterize the device and for service and diagnostic purposes. NOTE The most up-to-date version of the SICK Vision Suite software can be downloaded from www.sick.com/picoCam2...
  • Page 17: Maintenance

    Use a dry cloth or an industrial vacuum cleaner for cleaning. Do not use cleaning agents. 8025786/1HXT/2022-11 | SICK O P E R A T I N G I N S T R U C T I O N S | picoCam2...
  • Page 18: Troubleshooting

    The most up-to-date version of the SICK Vision Suite software can be downloaded from www.sick.com/picoCam2 under Downloads. In the case of faults that cannot be rectified, please contact the SICK Service depart‐ ment. To find your agency, see the final page of this document. NOTE Before calling, make a note of all type label data such as type designation, serial number, etc., to ensure faster assistance.
  • Page 19: Technical Data

    I2Dx03x: Sony IMX265 I2Dx05x: Sony IMX264 Shutter technology Global shutter 8025786/1HXT/2022-11 | SICK O P E R A T I N G I N S T R U C T I O N S | picoCam2 Subject to change without notice...
  • Page 20: Mechanics/Electronics

    3.45 μm 10.5 Interfaces Ethernet UDP/IP Data transmission rate 1,000 Mbit/s Configuration software SICK Vision Suite 10.6 Ambient data Impact load 80 g, EN 60068-2-27 (1995-03), EN 60068-2-29 (1995-03) Vibration load 10 g, 30 Hz ... 500 Hz, EN 60068-2-6 (1996-05) Ambient operating temper‐ 0 °C ... +55 °C ...
  • Page 21 Storage temperature –20 °C ... +60 °C  Relative humidity: 0 % ... 100 %. 8025786/1HXT/2022-11 | SICK O P E R A T I N G I N S T R U C T I O N S | picoCam2 Subject to change without notice...
  • Page 22: Accessories

    Accessories and, if applicable, mounting information can be found online at: • www.sick.com/picoCam2 O P E R A T I N G I N S T R U C T I O N S | picoCam2 8025786/1HXT/2022-11 | SICK Subject to change without notice...
  • Page 23: Annex

    The camera firmware uses the mbed TLS library under the Apache license, version 2.0 (http://www.apache.org/licenses). 8025786/1HXT/2022-11 | SICK O P E R A T I N G I N S T R U C T I O N S | picoCam2...
  • Page 24 Phone +7 495 283 09 90 E-Mail info@sick.com E-Mail office@sick.com.gr E-Mail info@sick.ru Vietnam Hong Kong Singapore Phone +65 6744 3732 Phone +852 2153 6300 Phone +65 6744 3732 E-Mail sales.gsg@sick.com E-Mail ghk@sick.com.hk E-Mail sales.gsg@sick.com Detailed addresses and further locations at www.sick.com SICK AG  |  Waldkirch  |  Germany  |  www.sick.com...

Table of Contents