Summary of Contents for SICK deTec4 C4C-EV03030A10000
Page 1
O P E R A T I N G I N S T R U C T I O N S deTec4 Core Vibes Safety light curtain...
Page 2
This work is protected by copyright. Any rights derived from the copyright shall be reserved for SICK AG. Reproduction of this document or parts of this document is only permissible within the limits of the legal determination of Copyright Law. Any modi‐...
Unpacking....................Installation....................5.3.1 Mounting the QuickFix bracket..........8024467/1GWF/2022-11-11 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes Subject to change without notice...
Page 4
14.3 Connectors....................14.4 Alignment aid.................... 14.5 Cleaning agent..................O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes 8024467/1GWF/2022-11-11 | SICK Subject to change without notice...
Page 5
List of figures..................65 List of tables..................66 8024467/1GWF/2022-11-11 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes Subject to change without notice...
This document: 8024467 • Available language versions of this document: 8024466 You can find the current version of all documents at www.sick.com. Target groups of these operating instructions Some sections of these operating instructions are intended for certain target groups.
The symbol indicates the sender. The symbol indicates the receiver. 8024467/1GWF/2022-11-11 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes Subject to change without notice...
Any instance of improper use, incorrect modification, or manipulation of the deTec4 Core Vibes safety light curtain shall void any warranty provided by SICK AG; further‐ more, SICK AG shall not accept any responsibility or liability for any resulting damage and consequential damage.
For maintenance, you must be able to assess if the machine is operating safely. 8024467/1GWF/2022-11-11 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes...
The sensing sensing range is dependent on the receiver used. O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes 8024467/1GWF/2022-11-11 | SICK Subject to change without notice...
The sender and receiver LEDs indicate the operational status of the safety light curtain. 8024467/1GWF/2022-11-11 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes...
Page 12
The blue alignment quality light emitting diodes in combination with the red flashing ERR LED also denote faults. O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes 8024467/1GWF/2022-11-11 | SICK Subject to change without notice...
Figure 5: Hazardous point protection Figure 6: Access protection 8024467/1GWF/2022-11-11 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes Subject to change without notice...
Page 14
PRODUCT DESCRIPTION Figure 7: Hazardous area protection O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes 8024467/1GWF/2022-11-11 | SICK Subject to change without notice...
O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes 8024467/1GWF/2022-11-11 | SICK Subject to change without notice...
Page 17
Laws: Code of Federal Regulations, Title 29 (CFR 29), Part 1910.217 b) Standards: ANSI B11.19 Complementary information More information is available in the ISO 13855 standard and in the Guide for Safe Machinery. SICK offers a stopping/run-down time measurement service in many countries. Further topics • "Response time", page 53 4.3.2.1...
Page 18
O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes 8024467/1GWF/2022-11-11 | SICK Subject to change without notice...
Make sure that no dispersive media (e.g., dust, fog, or smoke) are within the calculated minimum distance from the protective field. 8024467/1GWF/2022-11-11 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes...
= tan (2.5°) × 1,000 mm/m × D = 43.66 × 1 mm/m × O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes 8024467/1GWF/2022-11-11 | SICK Subject to change without notice...
2 is not affected by the infrared light from the sender 1. 8024467/1GWF/2022-11-11 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes...
The electrical control of the machine must meet the requirements of IEC 60204-1. 8024467/1GWF/2022-11-11 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes...
Page 24
Figure 17: No potential difference between load and protective device O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes 8024467/1GWF/2022-11-11 | SICK Subject to change without notice...
The external voltage supply of the protective device must be capable of buffering brief power failures of 20 ms as specified in IEC 60204-1. • The power supply unit must ensure safe isolation according to IEC 61140 (SELV/PELV). Suitable power supply units are available as accessories from SICK. Further topics • "Accessories", page 59 4.4.1...
Positively guided contactors are used for shutting down the machine. O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes 8024467/1GWF/2022-11-11 | SICK Subject to change without notice...
The definition must be based on the application conditions and the risk assess‐ ment and must be documented in a traceable manner. 8024467/1GWF/2022-11-11 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes...
The test is carried out with an opaque test rod whose diameter corresponds to the resolution of the safety light curtain. O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes 8024467/1GWF/2022-11-11 | SICK Subject to change without notice...
Page 29
The OSSD LED must not illuminate green. 8024467/1GWF/2022-11-11 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes...
The OSSD LED must not illuminate green. O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes 8024467/1GWF/2022-11-11 | SICK Subject to change without notice...
"Design", page 15 • "Technical data", page 51 Unpacking Approach Check the components for completeness and the integrity of all parts. In the event of complaints, contact the responsible SICK subsidiary. Further topics • "Ordering information", page 57 Installation Important information...
Notes on mounting Mount the sender and receiver on a level surface. (1) 8024467/1GWF/2022-11-11 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes...
Page 34
(3) O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes 8024467/1GWF/2022-11-11 | SICK Subject to change without notice...
Page 35
• "Minimum distance to reflective surfaces", page 19 8024467/1GWF/2022-11-11 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes Subject to change without notice...
A screw nut or threaded hole is required on the machine or profile frame (4). Tightening torque: 5 Nm … 6 Nm O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes 8024467/1GWF/2022-11-11 | SICK Subject to change without notice...
Page 37
Secure the position of the sensor and receiver in the bracket using the M5 screw. Torque: 2.5 Nm to 3 Nm 8024467/1GWF/2022-11-11 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes...
• Mounting has been correctly executed. O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes 8024467/1GWF/2022-11-11 | SICK Subject to change without notice...
System connection (M12, 5-pin) Figure 26: System connection (male connector, M12, 5-pin) 8024467/1GWF/2022-11-11 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes...
TGS safety light curtain with a deTec4 Core Vibes, without having to route new cables. O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes 8024467/1GWF/2022-11-11 | SICK Subject to change without notice...
Make sure that the outputs of the safety light curtain do not affect the machine during the alignment process. 8024467/1GWF/2022-11-11 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes...
"Indication of the alignment quality", page 43 • "Mounting", page 32 O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes 8024467/1GWF/2022-11-11 | SICK Subject to change without notice...
Remove all objects from the protective field to allow the alignment quality to be assessed. 8024467/1GWF/2022-11-11 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes...
Carry out the checks specified in the test plan of the manufacturer of the machine and the operating entity. O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes 8024467/1GWF/2022-11-11 | SICK Subject to change without notice...
Carry out the checks specified in the test plan of the manufacturer of the machine and the operating entity. 8024467/1GWF/2022-11-11 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes...
Do not use any aggressive cleaning agents. Do not use any abrasive cleaning agents. We recommend anti-static cleaning agents. We recommend the use of anti-static plastic cleaner (SICK part number 5600006) and the SICK lens cloth (SICK part number 4003353). Prerequisites •...
Carry out the checks specified in the test plan of the manufacturer of the machine and the operating entity. 8024467/1GWF/2022-11-11 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes...
Immediately put the machine out of operation if you cannot clearly identify or allocate the fault and if you cannot safely remedy the fault. Secure the machine so that it cannot switch on unintentionally. NOTE Additional information on troubleshooting can be found at the responsible SICK subsid‐ iary. 10.2 Diagnostic LEDs 10.2.1...
Page 49
LED off. Ö LED flashes. O LED illuminates. 8024467/1GWF/2022-11-11 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes...
Complementary information SICK will be glad to help you dispose of these devices on request. O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes...
The external voltage supply must be capable of bridging a brief power failure of 20 ms as specified in IEC 60204-1. Suitable power supply units are available as accessories from SICK. A fuse rated maximum 4 A shall be installed in the 24 V DC power supply circuit to the device in order to limit the available current.
Page 52
Length of cable 150 mm Cable diameter 4.3 mm Cable material O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes 8024467/1GWF/2022-11-11 | SICK Subject to change without notice...
1200 1350 1500 1650 1800 1950 2100 8024467/1GWF/2022-11-11 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes Subject to change without notice...
1120 1350 1240 1250 1500 1380 1390 O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes 8024467/1GWF/2022-11-11 | SICK Subject to change without notice...
1362 1500 1512 1650 1662 1800 1812 8024467/1GWF/2022-11-11 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes Subject to change without notice...
Page 56
O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes 8024467/1GWF/2022-11-11 | SICK Subject to change without notice...
C4C-EV13530C10000 1500 C4C-SV15030C10000 C4C-EV15030C10000 1650 C4C-SV16530C10000 C4C-EV16530C10000 8024467/1GWF/2022-11-11 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes Subject to change without notice...
Page 58
C4C-EV18030A10000 1950 C4C-SV19530A10000 C4C-EV19530A10000 2100 C4C-SV21030A10000 C4C-EV21030A10000 O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes 8024467/1GWF/2022-11-11 | SICK Subject to change without notice...
Ambient operating temperature: Down to −30° C with fixed installation. 8024467/1GWF/2022-11-11 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes Subject to change without notice...
Ambient operating temperature: Down to –30 °C with fixed installation O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes 8024467/1GWF/2022-11-11 | SICK Subject to change without notice...
Test rod 30 mm 2022602 Test rod holder 2052249 8024467/1GWF/2022-11-11 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes Subject to change without notice...
You can obtain declarations of conformity, certificates, and the current operating instructions for the product at www.sick.com. To do so, enter the product part number in the search field (part number: see the entry in the “P/N” or “Ident. no.” field on the type label).
Page 63
ISO 13849-1 GB/T 16855.1 ISO 13855 GB/T 19876 8024467/1GWF/2022-11-11 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes Subject to change without notice...
28. Dimensional drawing of sender and receiver............55 29. Dimensional drawing of the QuickFix bracket............59 8024467/1GWF/2022-11-11 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes...
30. Ordering information, test rods..................61 31. Note on standards...................... 62 O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes 8024467/1GWF/2022-11-11 | SICK Subject to change without notice...
Page 67
LIST OF TABLES 8024467/1GWF/2022-11-11 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 Core Vibes Subject to change without notice...
Page 68
Phone +7 495 283 09 90 E-Mail info@sick.com E-Mail office@sick.com.gr E-Mail info@sick.ru Vietnam Hong Kong Singapore Phone +65 6744 3732 Phone +852 2153 6300 Phone +65 6744 3732 E-Mail sales.gsg@sick.com E-Mail ghk@sick.com.hk E-Mail sales.gsg@sick.com Detailed addresses and further locations at www.sick.com SICK AG | Waldkirch | Germany | www.sick.com...
Need help?
Do you have a question about the deTec4 C4C-EV03030A10000 and is the answer not in the manual?
Questions and answers