Konica Minolta SRX-101A Service Manual page 100

Medical film processor
Hide thumbs Also See for SRX-101A:
Table of Contents

Advertisement

!8 P ut the inner cover and outer cover of the electrical components unit back to the original position.
!9 T here will be an area uncovered by the outer cover between bottom of the components housing and
the bottom of the light shield. Cut a piece of Packing(D)[thickness 5mm] into a strip of 450mm long
and attach it to the bottom of the electrical components housing.
@0 A ttach the square-shaped Packing(F) to the left and right sides of the light shield panel.
(4 pieces in total)
SRX-101A
@1 C ut pieces of Packing(C) into two strips of 200mm long and attach them to the left and right sides of
the light shield panel around the electrical components unit cover.
Left Light Shield
Packing(F)
Main Unit Stand
200mm Strips of
Packing(C)
INSTALLATION PROCEDURE
SRX-101A Electrical Components Unit Outer Cover
Components Housing
450mm Strip of Packing(D)
Upper Light Shield
Right Light Shield
(Do the same for the left side)
Lower Light Shield
Right Light Shield
Electrical Components Outer
Cover
Lower Light Shield
SERVICE MANUAL
95

Advertisement

Table of Contents
loading

This manual is also suitable for:

10511052

Table of Contents