Troubleshooting; Introduction - Troubleshooting; Fault Messages - Husqvarna Automower Aspire R4 Operator's Manual

Robotic lawn mower
Hide thumbs Also See for Automower Aspire R4:
Table of Contents

Advertisement

7.1 Introduction - troubleshooting

In this chapter you can find information and help about faults and symptoms of the product. You can find more
information and FAQ (Frequently Asked Questions) on www.husqvarna.com.

7.2 Fault messages

The fault messages in the table below are shown in the app. Speak to your Husqvarna service if the same message
shows frequently.
Message
Wheel motor blocked, left/
right
Cutting system blocked
Trapped
Outside working area

32 - Troubleshooting

7 Troubleshooting
Cause
Grass or other object around the drive
wheel.
Grass or other object around the blade
disc.
The blade disc is in water.
The grass is too high.
The product is behind a number of obsta-
cles in a small area.
A section of boundary wire is put across
the other section of boundary wire to the
charging station.
The boundary wire is too near the edge of
the work area.
The work area slopes much by the boun-
dary loop.
The boundary wire is put in the incorrect
direction around an island.
Interference to the boundary wire from
metal objects such as fences, reinforce-
ment steel or buried cables nearby.
The product can not find the correct loop
signal because of interference with a loop
signal from a different product installation
nearby.
Action
Remove grass or other object.
Remove grass or other object.
Move the product and prevent the collec-
tion of water in the work area.
Cut the grass before you install the prod-
uct. Make sure that the grass is maximum
4 cm / 1.6 in.
Remove the obstacles or put the boundary
wire around the obstacle to make an is-
To make an island on page
land. Refer to
15 .
Make sure that the boundary wire is con-
nected correctly.
Make sure that the boundary wire is instal-
To install the boun-
led correctly. Refer to
dary wire on page 18 .
Move the boundary wire.
Put the product in the charging station and
generate a new loop signal.
1886 - 001 - 01.02.2023

Advertisement

Table of Contents
loading

Table of Contents