Cabling Examples - Paradyne 5011 Installation Instructions Manual

Pots splitter central office
Hide thumbs Also See for 5011:
Table of Contents

Advertisement

Cabling Examples

12
To connect 24 pairs from two POTS splitter cards to the DSLAM, use a Y-cable.
The DSLAM connector feeds 24 DSL ports, comprised of six slots with four ports
per DSL card slot.
Interface connections:
DSL Interface connects to the 8800 DSLAM using a Y-cable. The Y-cable
enables 24 POTS splitters to serve 24 DSL lines on the DSLAM.
LOOP Interface connects to the local loop via the main distribution frame.
PSTN Interface connects to the local PSTN switch.
In the next example, the first two POTS splitter cards are combined using the
Y-cable, part number 8000-F1-001.
Main Distribution
Frame
Cross-Connect
Block
Y-Cable
March 1998
Six-Card
POTS
Splitter
Chassis
To
PSTN
POWER
ALARMS
Switch
A
B
Fan
Major Minor
8800
DSLAM
Chassis
A
B
98-15804-01
5020-A2-GN10-20

Advertisement

Table of Contents
loading

This manual is also suitable for:

5016Hotwire 5020

Table of Contents