Replacement Of Main Parts; Precautions Before Work; Non-Reusable Parts; Tightening Torque - Sony PWS-110RX1A Service Manual

Network rx station and optional power supply
Hide thumbs Also See for PWS-110RX1A:
Table of Contents

Advertisement

5-1.

Precautions before Work

5-1-1.

Non-reusable Parts

• Radiation sheet (CPU)
Radiation sheet (CPU) is not reusable. Prepare new parts in advance.
5-1-2.

Tightening Torque

Be sure to use a torque driver and tighten screws to the specified tightening torque.
Tightening torque
M2: 0.30 ±0.02 N·m
M2.6: 0.53 ±0.07 N·m
M3: 0.80 ±0.12 N·m
M4: 1.4 ±0.2 N·m
Tip
When using the torque driver with the notation of cN· m, interpret it as follows.
Example: 0.8 N·m = 80 cN·m