ALIGNMENT (continued)
Automatic with Thoma
Connect color analyzer to the monitor.
Calibrate color analyzer for offset.
Position color analyzer in center of screen.
Select continuous XYZ mode. Avoid incident light.
To return :
CLEAR
To start
:
ENTER
MOUNT THE COLORHEAD AFTER THE MONITOR HAS BEEN
TURNED ON AND ONLY IF THE COLOR ANALYZER
HAS BEEN CONNECTED TO THE CVS.
PICTURE TUBE FLASHES OR SWITCHING THE MONITOR
CAN DAMAGE THE CIRCUITRY OF THE COLOR ANALYZER
Connect the colorhead to the color analyzer. Connect the color
analyzer to the monitor.
Turn on the analyzer : press ON.
For precise measurements, offset calibration is required : cover the
colorhead to block incident light and press Abj.
If a Thoma TMF-2, press CON (for continuous measurement).
Press XYZ (standard color values for red-green-blue).
The automatic alignment starts now. When finished, the monitor
will return tot the previous menu. Now you can select other colour
temperatures or return to other menu's. If the alignment was
successful, it will be indicated in the STATUS column as passed.
ALIGNMENT (continued)
Automatic with probe
The "Automatic with probe" alignment option is only useful for
owners of a Barco Light probe, a probe designed for CVS, AVM,
CVM-A and CVM20XX monitors.
Refer to the Barco Light Probe manual for more information.
26