Upgrading From Sl-1 N (Qca58 Ce Cabinet) To Meridian 1 - Nortel Meridian SL-1 Supplementary Manual

Shelf upgrades to meridian 1 system options 21, 61, 71
Hide thumbs Also See for Meridian SL-1:
Table of Contents

Advertisement

6-4 Upgrading from SL-1 N (QCA58 cabinet) to Option 61

Upgrading from SL-1 N (QCA58 CE cabinet) to Meridian 1

Option 61
Shelf upgrades to Meridian 1 553-3001-253
1
Obtain printouts of all the characteristics (TN, loop, telephones and all
other assignments and features) of the existing system. Retain these
printouts for an after conversion check.
2
Using overlay program 43, perform a data dump.
3
Remove the covers from the CE cabinet.
4
Invoke emergency line transfer by setting the line transfer switch on
all QPC84 Power Monitor circuit packs to ON or 1.
Set the -48 V cabinet input breaker located on the power control
shelf or power distribution box in the CE cabinet to OFF.
Tag and disconnect the cables from all the faceplate connectors of
circuit packs located on the QSP41 CPU/MEM shelf.
Remove all circuit packs from the CPU/MEM shelf.
Tag and disconnect cables A, B, C and D from the end of the
CPU/MEM shelf.
Tag and disconnect the four power and ground leads connected to
the lugs on the end of the shelf backplane.
5
Remove mounting screws securing CPU/MEM shelf to cabinet frame
and remove shelf from cabinet.
Position new QSD60 CPU/MEM shelf in the position vacated by
the QSP41 CPU/MEM shelf and secure to cabinet frame with four
mounting screws.
6
Connect:
the four power and ground leads from cabinet power wiring
harness to the -48V 0, -48V 1, -48V GND and L GND lugs on the
end of the new CPU/MEM shelf backplane (Figure 6-1).
cables A, B, C and D to the connectors on the end of the shelf
(Figure 6-2).