Page 46 of 284
Performing the upgrade
Database requirements
Upgrading Core 1
NN43021-469 Standard 01.01 May 2007
If the system is running pre-release 23 software or the source platform is a
Meridian 1 Option 21E, 51, 61, 71, STE, NT or XT, the database must be sent
to Nortel for conversion.
If the source platform is a Meridian 1 Option 51C, 61C, 81, or 81C equipped
with IOP/CMDU cards, the database must be converted with the Database
Transfer utility.
If the source platform is a Meridian 1 Option 51C, 61C, 81, or 81C equipped
with IODUC cards, the database should be data dumped (EDD) to a blank
2 MB floppy.
Note: All of the above listed system types can be converted by Nortel in
the software conversion lab. Please check the current price manual for
the requirements of this service.
Procedure 5
Checking main Core card installation
The main Core cards, including the MMDU (with the cables for power and
data), are installed in the factory as shown in Figure 3 on
1
NT4N65AB CP PII Core Network Interface (cCNI) cards:
Each system contains 1-4 NT4N65 cCNI card per Core/Net module. The
cCNI cards are located in slot c9-c12. If not already installed, install a
P0605337 CP PII Card Slot Filler Panel to cover slots which do not
contain cCNIs.
Note: In the NT4N40 Core/Net card cage, port 0 on the NT4N65 Core to
Network Interface (cCNI) Card in slot c9 must be configured as "group 0."
Port 1 on this card must be configured as group 1. The cCNI and 3PE
cards for group 0 communicate through the NT4N29 cables. The cCNi to
3PE cables for groups 1 to 7 communicate through the NTND14 cables.
2
Slots c13 and c14 are left empty. If not already installed, install a
P0605337 CP PII Card Slot Filler Panel in each slot.
3
NT4N48 System Utility (Sys Util) card is located in slot c15.
page
48: