5-4 Upgrading from SL-1 N (QCA23 cabinet) to Option 61

Upgrading from SL-1 N (QCA23 CE cabinet) to Meridian 1

Option 61
Shelf upgrades to Meridian 1 553-3001-253
1
Obtain printouts of all the characteristics (TN, loop, telephones and all
other assignments and features) of the existing system. Retain these
printouts for an after conversion check.
2
Using overlay program 43, perform a data dump.
3
Remove the covers from the CE cabinet.
Note: The system service will be interrupted and emergency service
(if provided) will be connected.
4
Invoke emergency line transfer by setting the line transfer switch on
all QPC84 Power Monitor circuit packs to ON or 1.
Set the -48 V cabinet input breaker located on the power control
shelf or power distribution box in the CE cabinet to OFF.
Tag and disconnect the cables from all the faceplate connectors of
circuit packs located on the QSD37 CPU/MEM shelf.
Remove all circuit packs from the CPU/MEM shelf.
Tag and disconnect cables A, B, C and D from the end of the
CPU/MEM shelf.
Tag and disconnect the four power and ground leads connected to
the lugs on the end of the shelf backplane.
5
Remove mounting screws securing CPU/MEM shelf to cabinet frame
and remove shelf from cabinet.
Position new QSD59 CPU/MEM shelf in the position vacated by
the QSD37 CPU/MEM shelf and secure to cabinet frame with
four mounting screws.
6
Connect:

Hide quick links: