Electrical Connection; Peak-Load Negotiation - Miele PFD 401 Marine Operating Instructions Manual

Commercial dishwasher
Hide thumbs Also See for PFD 401 Marine:
Table of Contents

Advertisement

Electrical connection

Electrical connection
 Danger caused by improper electrical
connection
All electrical work must be carried out by
a suitably qualified electrician in
accordance with local and national safety
regulations.
Ask a qualified specialist to complete the
electrical connection work.
- The electrical installation must be in
compliance with current local and national
safety regulations (DIN VDE 0100 in
Germany).
- The connection to the power supply must
comply with national regulations (plug and
socket must be accessible after the
machine has been installed). An electrical
safety test can then easily be carried out
in line with VDE 0701, e.g. after any
service or maintenance work.
- It is recommended to connect the product
with a suitably rated plug and socket.
- If the dishwasher is hard wired to the
power supply, connection should be
made via a mains switch with all-pole
isolation. The mains switch must ensure a
gap of at least 3 mm between all open
contacts and must be able to be locked in
the off position.
- For increased safety, it is recommended
to protect the machine with a suitable
residual current device (RCD Type A) with
a trip current of 30 mA (DIN VDE 0664).
- Equipotential bonding should be carried
out if required.
- The mains connection cable may only be
replaced by an original Miele spare part.
- For technical data, see the data plate or
wiring diagram supplied.
The machine must only be operated with
the voltage, frequency and fuse rating
shown on the data plate.
98
This machine can be converted to a
different type of power supply in
accordance with the conversion diagram
and wiring diagram supplied.
The conversion diagram and the data
plate are on the dishwasher or supplied
with it.
Equipotential bonding connection
There is a screw connection point marked 
at the back of the dishwasher, to which
additional equipotential bonding can be
connected.

Peak-load negotiation

The dishwasher is suitable for use in an
energy management system. For this
purpose, the dishwasher must be
technically adapted and the controls reset
by the Miele Customer Service Department.
Please contact the Miele Customer Service
Department for further information.
Load management
In the event of a peak-load negotiation,
some dishwasher components, such as the
heater elements, will be switched off for a
while. The dishwasher will remain on during
this period and the current programme will
not be interrupted. If one of the components
that is switched off is needed during the
current programme stage, the programme
running time will simply increase for the
duration of the load negotiation.
Load negotiation is indicated by the
following message, e.g.:
Peak-load negotiation:
heating mode temporarily
Information
disabled.