AUMA SQEx 05.2 Manual page 10

Part-turn actuators
Hide thumbs Also See for SQEx 05.2:
Table of Contents

Advertisement

Name tag
Order number (commis-
sion number)
Ex marking
Actuator serial number
10
SQEx
07.2
-FA10
FA10 Flange size
The product can be identified using this number and the technical data as well as or-
der-specific data pertaining to the device can be determined.
Please always state this number for any product inquiries.
Table 3: Description of the Ex marking with the example of /13B1111
Marking for the explosion protection (with the example of /13B1111)
/
1
3
B
1
1
Version (actuator with/without actuator controls)
1
1 = NORM (without actuator controls)
Electrical connection
3
3 = Terminal connection type: KES-Ex d (terminal compartment Ex d flameproof enclosure)
Cover of control unit
B
B = without indicator glass
W = with indicator glass
Motor heater
1
1 = without motor heater
2 = with motor heater
1
Table 4: Serial number until 2022, description with the example of 0520NS12345
05
22
NS12345
05
Positions 1+2: Assembly in week = week 05
22
Positions 3+4: Year of manufacture = 2022
NS12345
Internal number for unambiguous product identification
Table 5: Serial number as of 2023, description with the example of 0000-00101-2023
00000-00101
- 2023
Serial number of sales article
00000-00101
11-digit internal number for unambiguous product identification
2023
Year of manufacture = 2023
1
1
Motor insulation class
1 = Insulation class F
2 = Insulation class H
Not applicable
1
without signification
Motor type
1
a = VD. or SD.: 3-phase AC motor

Advertisement

Table of Contents
loading

Table of Contents