5.1.2.1.2
Kontron IPMB-L Link
Table 5-3:Kontron IPMB-L Link sensor
Event/Reading type
Sensor type
code
C3h
6Fh
OEM Kontron
IPMB-L Link
5.1.2.1.3
Kontron MMC Firmware Upgrade Status
Table 5-4:Kontron MMC FW upgrade status sensor
Event/Reading type
Sensor type
code
CAh
OEM Kontron
External
6Fh
Component
Firmware Upgrade
Status
Sensor specific offset
Event trigger
IPMB-L Disable
Event Data 2: always 0
Event Data 3:
bit[7:3]: always 0
bit [2:0]:
0h = no failure
1h = Unable to drive clock HI
02h
2h = Unable to drive data HI
3h = Unable to drive clock LO
4h = Unable to drive data LO
5h = clock low timeout
6h = Under test (the IPM Controller is attempting to
determine who is causing a bus hang)
7h = Undiagnosed Communication Failure
IPMB-L Enable
Event Data 2: always 0
Event Data 3:
bit[7:3]: always 0
bit [2:0]:
0h = no failure
1h = Unable to drive clock HI
03h
2h = Unable to drive data HI
3h = Unable to drive clock LO
4h = Unable to drive data LO
5h = clock low timeout
6h = Under test (the IPM Controller is attempting to
determine who is causing a bus hang)
7h = Undiagnosed Communication Failure
Sensor specific offset
Event trigger
00h
Firmware Upgrade in Progress (no event)
01h
Firmware upgrade succeeded
02h
Firmware upgrade failed
34
AM4211
www.kontron.com