Field Replaceable Unit (Fru) Information; Table 5-7 Voltage Sensor Thresholds - Kontron AdvancedMC AM4211 User Manual

Table of Contents

Advertisement

5.1.2.2
Sensor Thresholds
Following table shows sensor thresholds for voltages
Table 5-7:Voltage sensor thresholds
SENSOR Number / ID string
Vcc +3.3VSUS
Vcc +12V In
Vcc Vcore
Vcc +1.1V
Vcc +1.5V
Vcc +1.8V
Vcc VTT_DDR
Vcc +2.5V
Vcc +1.2V
Vcc +1.0V BCM
Vcc +3.3V
Vcc +1.2V SUS
Vcc +5V
Note:
Lower non critical and upper non critical values are not set to ensure no error in normal operation.
Note:
Vcc +1.8V Sensor is only monitored when the SyncE option is installed.
5.1.3

Field Replaceable Unit (FRU) Information

This FRU information contains the IPMI defined Board and Product Information areas that hold the part
number and serial number of the board and the Multirecord Information Area that contains the PICMG
defined Module Current Requirement Record, the AMC Point-to-Point Connectivity Record and the Clock
Configuration Record.
The Internal Use Area is pre-allocated to 384 bytes and is free for customer use.
This FRU information responds to FRU ID #0, which is the ID for the MMC.
Lower Non-Re-
Lower criti-
coverable
cal
2.802V
2.955V
8.152V
9.826V
0.987V
1.087V
0.971V
1.032V
1.321V
1.423V
1.062V
1.682V
0.643V
0.682V
2.197V
2.342V
0.907V
1.120V
0.569V
0.932V
2.951V
3.093V
1.053V
1.114V
4.126V
4.126V
36
Lower non crit-
Upper non
ical
critical
critical
-
-
3.623V
-
-
14.244V
-
-
1.165V
-
-
1.170V
-
-
1.579V
-
-
1.920V
-
-
0.821V
-
-
2.660V
-
-
1.312V
-
-
1.051V
-
-
3.512V
-
-
1.289V
-
-
5.597V
www.kontron.com
Upper
Upper Non-Re-
coverable
3.806V
15.918V
1.230V
1.231V
1.681V
2.540V
0.860V
2.805V
1.525V
1.414V
3.654V
1.350V
5.597V
AM4211