Power Supply

The CSE-506TS-R301P chassis has two 300W AC hot-swappable redundant power supplies.
The power supplies are auto-switching capable. If replacing a power supply, the system
does not need to be powered down. New units can be ordered directly from Supermicro or
authorized distributors.
Replacing a Power Supply
1. Use the system's remote management to find the failed power supply.
2. Check the power supply's LED.
LED
3. Disconnect the power cord from the power strip or outlet.
4. Disconnect the power cord from the power supply inlet.
5. Push the release tab on the back of the power supply as illustrated.
6. Using the handle, pull the power supply out of the chassis.
7. Slide the new power supply into the chassis until it clicks into place.
8. Reconnect the power cord to the power supply inlet.
9. Reconnect the power cord to the power strip or outlet.
10. Check the power supply's LED.
11. Use remote management to check the power supply status.
Chapter 3: Maintenance and Component Installation
Power Supply LED States
LED Color
Definition
Off
No power input
Amber
Power supply is off or failed
Green
Power supply is on and operating
Figure 3-12. Power Supply Rear View