Abnormal Panel Temperature - Sony TRIMASTER EL BVM-E171 Service Manual

Professional video monitor
Hide thumbs Also See for TRIMASTER EL BVM-E171:
Table of Contents

Advertisement

When VDDDS is output for about 48 ms but it stops again
Factor
An abnormality of the power on the
VCATH side is considered.
When VDDDS is not output
Factor
An abnormality of the power on the
VDDDS side is considered.
3-3-2.

Abnormal Panel Temperature

Factor
• Installation environment
- Environmental temperature, exhaust function failure or no space around this unit
- Detected panel temperature: 65 ℃ or more (Refer to
Temperature".)
• Luminance setting
- High luminance state
• Connection failure
Unit status at an error
The DC-DC converter for the panel power on the BC board is shut down.
Applicable parts (Generated voltage line name)
• IC8600 (VSSWS, VSS1DS, VSS2DS)
• IC8605 (VOFS1)
• IC8700 (VGMA, VDD_DRV)
• IC8701 (VDDWS)
• IC9000 (VDDDS)
• IC9001 (VCATH)
Remedy
• Check the installation environment.
If the environment temperature is higher than the recommended temperature, lower it.
If there is something that blocks the fan exhaust outlet or ventilation outlet in the rear portion of this unit, remove
it.
Ensure the space around this unit for ventilation.
BVM-E171
Remedy
1.
Check whether the fuses (F9002, F9003, F9004, F9005) are blown. If any of
these fuses is blown, replace defective parts.
When F9002 is blown:
Check whether the following parts are damaged.
Q9006, Q9007, C9036, D9008, D9009
When F9003 is blown:
Check whether the following parts are damaged.
Q9008, Q9009, C9037, D9010, D9011
2.
Check whether the protection diodes (D9012, D9013) are damaged. If any of
these diodes is damaged, replace defective parts.
Check whether a short-circuit is present in the forward or reverse direction.
Remedy
Check whether the fuses (F9000, F9001) are blown. If any of these fuses is blown,
replace defective parts.
When F9000 is blown:
Check whether the following parts are damaged.
Q9002, Q9003, C9034, D9004, D9005
When F9001 is blown:
Check whether the following parts are damaged.
Q9004, Q9005, C9035, D9006, D9007