Sony TRIMASTER EL BVM-E171 Service Manual page 33

Professional video monitor
Hide thumbs Also See for TRIMASTER EL BVM-E171:
Table of Contents

Advertisement

3G-SDI INPUT1
+3.3V_OP_D_A_SDI1
C2403
0.01u
50V
X7R
C2404
0.047u
25V
X7R
C2405
0.22u
16V
X7R
1608
EQ1_SDOP
R2401
10k
1%
EQ1_SDOM
R2404
4.7k
1/16W
GND
+3.3V_OP_D_A_1
SDI 2 Signal Is Not Displayed
Factor
This is considered the failure of IC2202
or IC2403 on the BA board.
BVM-E171
R2408
22
1
LF+
2
CP_CAP
IC2401
3
GS2965-INTE3
DDI0
4
HIF
5
3G-SDI
DDI0
6
CABLE RECLOCKER
DDI1
7
DDI1
R2405
8
4.7k
RSVD
1/16W
R2402
R2406
820
12
1%
1%
R2403
C2410
820
10u
1%
6.3V
X6S
2012
C2414
C2415
C2411
GND
0.01u
0.22u
1u
50V
16V
6.3V
X7R
X7R
X6S
1608
C2412
0.01u
50V
X7R
Remedy
1.
Input the SDI signal to SDI 2 INPUT.
2.
Measure the C2451 waveform.
Connect and disconnect the SDI signal and check whether there is a change in
the C2451 waveform.
3.
When there is no change and the R2433 voltage is 3.3 V while the SDI
signal is input:
Replace IC2403
When the R2433 is at the ground level or unstable level while the SDI
signal is input:
Replace IC2202
AT3_REC1_SDI_SDIN
REC1_REC2_SDI_SDOUT
AT3_REC_SDI_SCLK
C2426
AT3_REC_SDI_CS_X
18p
50V
X2400
CH
27MHz
R2414
1M
R2415
C2427
GND
1k
10p
1/16W
50V
CH
C2428
24
C2420
4.7u
VEE_DDO0
C2428
0.01u
6.3V
23
50V
X6S
VCC_DDO0
X7R
1608
22
1005
DDO0
21
DDO0
20
C2421
C2429
VEE_DDO1
4.7u
0.01u
19
50V
6.3V
VCC_DDO1
X6S
X7R
18
GND
1608
1005
DDO1/RCO
17
DDO1/RCO
+3.3V_OP_D_A_1
R2411
22
REC1_AT3_SDI_SD_HD_X
R2412
22
REC1_AT3_SDI_LOS
R2413
22
REC1_AT3_SDI_LKED
R2413
3G-SDI_IN1_SDOP
3G-SDI_IN1_SDOM
JC2400
0
3G-SDI_OUT1_SDOP
3G-SDI_OUT1_SDOM
JC2401
0
3-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trimaster el bvm-e251

Table of Contents