NEC BladeServer Express5800 Series User Manual page 38

Hide thumbs Also See for BladeServer Express5800 Series:
Table of Contents

Advertisement

Virtual LCD indications when STATUS lamp is flashing red
On-screen message
Proc 1 IERR
Proc 2 IERR
WDT Timeout
WDT Power Down
SMI Timeout
ErrPause in POST
DUMP Request !
Memory U-Err XX
Proc Missing
Proc1 Config Err
Proc2 Config Err
BB Mez1 PwFault
BB Mez2 PwFault
DAS Mez1 PwFault
DAS Mez2 PwFault
Description
An error was detected in CPU#1.
An error was detected in CPU#2.
Watchdog timer timeout error
occurred.
Forcibly powered off due to
watchdog timer timeout error.
A timeout error occurred while
the system management
interrupt process is in progress.
The system is waiting for key
entry due to serious POST error.
Under memory dump request.
An uncorrectable memory error
was detected. XX denotes the
DIMM slot number with 1-origin
that contains the failed DIMM.
No CPU is installed in slot
CPU#1.
The CPU installed in the CPU#1
slot is unsupported or its
combination is illegal.
The CPU installed in the CPU#2
slot is unsupported or its
combination is illegal.
An error was detected in power
circuit of mezzanine card
installed in Type I slot of CPU
unit.
An error was detected in power
circuit of mezzanine card
installed in Type II slot of CPU
unit.
An error was detected in power
circuit of mezzanine card
installed in Type I slot of CPU
unit.
An error was detected in power
circuit of mezzanine card
installed in Type II slot of CPU
unit.
General Description 2-13
Action
1. Turn off the power and then turn
it on again.
2. If an error message appears on
the POST screen, check the
message.
3. If no error message appears,
check the system by using the
Off-line Maintenance Utility.
Check the error message on the
POST screen.
Wait until dump collection
completes.
1. Check the installation status of
the DIMM.
2. Replace the DIMM.
Check the installation status of the
CPU.
Check if the installed CPU is
supported by the system.
Check the CPU combination, such
as the frequency of CPU#1 and
CPU#2.
1. Check the installation status of
the mezzanine card.
2. Replace the mezzanine card.